Establishing ground truth of polyp size, morphology, and volume using three-dimensional scanning

Roupen Djinbachian iD, Mahsa Taghiakbari, Firas Mubaid, Chakib Yahia Rekkabi, Bibi Nuzha Noorah, Daniel von Renteln iD

Endoscopy · 01.12.2023 · 55 (S 01 S 01) · E1260-E1261

DOI: 10.1055/a-2210-0635 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Roupen Djinbachian und 5 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology, Centre Hospitalier de l'Université de Montréal, Montreal, Canada. Hauptthemen laut MEDLINE: Colonography, Computed Tomographic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 3 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fujifilm Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Establishing ground truth of polyp size, morphology, and volume using three-dimensional scanning Comprehensive artificial intelligence (AI) solutions that should cover detecting polyp morphology, size, and volume are being developed. To train such AI solutions, it is essential to obtain high quality reference (ground truth data) on polyp morphology, size, and volume. We explored the feasibility of three-dimensional (3D) scanning of colorectal polyps to obtain computer-aided design (CAD) 3D rendering information on polyp morphology, size, and volume. During the colonoscopy, a novel virtual scale endoscope (VSE; Scale eye, EW10-VM01; Fujifilm, Tokyo, Japan) with an integrated virtual scale function was used, which allows for polyp size measurement [ 1 ] [ 2 ] [ 3 ] ([ Video 1 ]). Two detected polyps had their size measured during the colonoscopy using VSE ([ Fig. 1 ] a,d ), then were removed from the colon as intact en bloc specimens with a healthy resection margin. The polyps were measured using a digital Vernier caliper (eSync with 32 feeler gauge with 0.01-mm intervals) directly after resection ([ Fig. 1 ] b,e ). The polyps were then 3D scanned for volumetric information (Artec Space Spider; Artec 3D, Luxembourg) [ 4 ] ([ Fig. 1 ] c,f ). The 3D scanner processes up to 1 million individual points per second at 7.5 frames per second with a resolution of 0.1 mm. Polyp 1 was measured as being 8 mm using the VSE, 8.88 mm using the caliper, and 9.68 mm in the 3D model. The total polyp volume was 291.8 mm 3 . Polyp 2 was measured as being 14 mm using the VSE, 15.16 mm using the caliper, and 15.20 mm in the 3D model. The total polyp volume was 968.1 mm 3 . Quality: mobile 360 480 720 Download Two polyps are measured using a virtual scale endoscope (VSE) and then by subsequent 3D rendering after their resection.Video 1 Fig. 1 Images showing the measurement of two polyps using: a,d the virtual scale endoscope; b,e a vernier caliper; c,f 3D rendering after the polyps’ resection. We found that it is possible to obtain spatial polyp information through 3D scanning. 3D scanning of polyps can capture their shape, geometries, and textures, translating them into data files in which size, volume, and shape becomes measurable. These 3D models can then be used in the context of AI development to provide ground truth data to train models to automatically recognize size, volume, and Paris classification. Endoscopy_UCTN_Code_CPL_1AJ_2AB Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 21 December 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Colonography, Computed TomographicHumansImaging, Three-Dimensional

Autor:innen und Institutionen

  • Gastroenterology, Centre Hospitalier de l'Université de Montréal, Montreal, Canada.
  • Gastroenterology, Centre de Recherche du Centre Hospitalier de l'Universite de Montreal, Montreal, Canada.
  • Division of Internal Medicine, Centre Hospitalier de l'Université de Montréal, Montreal, Canada.

ORCID-Profile: Roupen Djinbachian, Daniel von Renteln

Förderung

  • Fujifilm Corporation

Zitieren

APA

Djinbachian, R., Taghiakbari, M., Mubaid, F., Rekkabi, C. Y., Noorah, B. N., & von Renteln, D. (2023). Establishing ground truth of polyp size, morphology, and volume using three-dimensional scanning. Endoscopy, 55(S 01 S 01), E1260-E1261. https://doi.org/10.1055/a-2210-0635

Vancouver

Djinbachian R, Taghiakbari M, Mubaid F, Rekkabi CY, Noorah BN, von Renteln D. Establishing ground truth of polyp size, morphology, and volume using three-dimensional scanning. Endoscopy. 2023;55(S 01 S 01):E1260-E1261. doi:10.1055/a-2210-0635

BibTeX
@article{Djinbachian2023,
  author = {Djinbachian, Roupen and Taghiakbari, Mahsa and Mubaid, Firas and Rekkabi, Chakib Yahia and Noorah, Bibi Nuzha and von Renteln, Daniel},
  title = {Establishing ground truth of polyp size, morphology, and volume using three-dimensional scanning},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 01 S 01},
  pages = {E1260--E1261},
  doi = {10.1055/a-2210-0635}
}
Kostenlos starten →