EUVIMEDEUVIMED entdecken
Crossref

One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist

Douglas K Rex, Jackson A Gallagher, Rachel E Lahr, Krishna C Vemulapalli, Prateek Sharma, Cesare Hassan

Endoscopy · 01.02.2024 · 56 (02) · 102-107

DOI: 10.1055/a-2189-2679 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.02.2024. Verfasst von Douglas K Rex und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, United States. Hauptthemen laut MEDLINE: Colonic Polyps, Colorectal Neoplasms. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cold forceps and snares are each effective for removing polyps of 1–3 mm, while snares are more effective for polyps of 4–10 mm in size. If, in the same patient, polyps of 1–3 mm are removed with forceps and those of 4–10 mm with snares, two devices are used. If cold snares are used to resect all lesions of 1–10 mm (one-device colonoscopy), there is a potential for lower costs and less plastic waste.

Methods

A single high detecting colonoscopist prospectively measured the feasibility of cold snaring all colorectal lesions of ≤10 mm in size, along with the associated costs and plastic waste reduction.

Results

677 consecutive lower gastrointestinal endoscopies (not for inflammatory bowel disease) were assessed. Of 1430 lesions of 1–3 mm and 1685 lesions of 4–10 mm in size, 1428 (99.9%, 95%CI 99.5%–100%) and 1674 (99.3%, 95%CI 98.8%–99.7%), respectively, were successfully resected using cold snaring. Among 379 screening and surveillance patients, universal cold snaring of lesions ≤10 mm saved 35 and 47 cold forceps per 100 screening and surveillance patients, respectively.

Conclusion

Cold snare resection of all lesions ≤10 mm (one-device colonoscopy) was feasible, and reduced costs and plastic waste.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Colonic PolypsColorectal NeoplasmsHumansColonoscopyCost SavingsFeasibility StudiesMicrosurgery

Autor:innen und Institutionen

  • Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, United States.
  • Division of Gastroenterology, Hepatology and Motility, University of Kansas School of Medicine, Kansas City, United States.
  • Department of Gastroenterology, Kansas City VA Medical Center, Kansas City, United States.
  • Department of Biomedical Sciences, Humanitas University, Milan, Italy.
  • Endoscopy Unit, IRCCS Humanitas Research Hospital, Rozzano, Italy.

Zitieren

APA

Rex, D. K., Gallagher, J. A., Lahr, R. E., Vemulapalli, K. C., Sharma, P., & Hassan, C. (2024). One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist. Endoscopy, 56(02), 102-107. https://doi.org/10.1055/a-2189-2679

Vancouver

Rex DK, Gallagher JA, Lahr RE, Vemulapalli KC, Sharma P, Hassan C. One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist. Endoscopy. 2024;56(02):102-107. doi:10.1055/a-2189-2679

BibTeX
@article{Rex2024,
  author = {Rex, Douglas K and Gallagher, Jackson A and Lahr, Rachel E and Vemulapalli, Krishna C and Sharma, Prateek and Hassan, Cesare},
  title = {One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist},
  journal = {Endoscopy},
  year = {2024},
  volume = {56},
  number = {02},
  pages = {102--107},
  doi = {10.1055/a-2189-2679}
}
Kostenlos starten →