One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist
Endoscopy · 01.02.2024 · 56 (02) · 102-107
DOI: 10.1055/a-2189-2679 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.02.2024. Verfasst von Douglas K Rex und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, United States. Hauptthemen laut MEDLINE: Colonic Polyps, Colorectal Neoplasms. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Background
Cold forceps and snares are each effective for removing polyps of 1–3 mm, while snares are more effective for polyps of 4–10 mm in size. If, in the same patient, polyps of 1–3 mm are removed with forceps and those of 4–10 mm with snares, two devices are used. If cold snares are used to resect all lesions of 1–10 mm (one-device colonoscopy), there is a potential for lower costs and less plastic waste.
Methods
A single high detecting colonoscopist prospectively measured the feasibility of cold snaring all colorectal lesions of ≤10 mm in size, along with the associated costs and plastic waste reduction.
Results
677 consecutive lower gastrointestinal endoscopies (not for inflammatory bowel disease) were assessed. Of 1430 lesions of 1–3 mm and 1685 lesions of 4–10 mm in size, 1428 (99.9%, 95%CI 99.5%–100%) and 1674 (99.3%, 95%CI 98.8%–99.7%), respectively, were successfully resected using cold snaring. Among 379 screening and surveillance patients, universal cold snaring of lesions ≤10 mm saved 35 and 47 cold forceps per 100 screening and surveillance patients, respectively.
Conclusion
Cold snare resection of all lesions ≤10 mm (one-device colonoscopy) was feasible, and reduced costs and plastic waste.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, United States.
- Division of Gastroenterology, Hepatology and Motility, University of Kansas School of Medicine, Kansas City, United States.
- Department of Gastroenterology, Kansas City VA Medical Center, Kansas City, United States.
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.
- Endoscopy Unit, IRCCS Humanitas Research Hospital, Rozzano, Italy.
Zitieren
APA
Rex, D. K., Gallagher, J. A., Lahr, R. E., Vemulapalli, K. C., Sharma, P., & Hassan, C. (2024). One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist. Endoscopy, 56(02), 102-107. https://doi.org/10.1055/a-2189-2679
Vancouver
Rex DK, Gallagher JA, Lahr RE, Vemulapalli KC, Sharma P, Hassan C. One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist. Endoscopy. 2024;56(02):102-107. doi:10.1055/a-2189-2679
BibTeX
@article{Rex2024,
author = {Rex, Douglas K and Gallagher, Jackson A and Lahr, Rachel E and Vemulapalli, Krishna C and Sharma, Prateek and Hassan, Cesare},
title = {One-device colonoscopy: feasibility, cost savings, and plastic waste reduction by procedure indication, when performed by a high detecting colonoscopist},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {02},
pages = {102--107},
doi = {10.1055/a-2189-2679}
}
EUVIMED