Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Takeshi Ogura und 4 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy Center, Osaka Medical and Pharmaceutical University, Takatsuki, Japan. Hauptthemen laut MEDLINE: Stents, Laparoscopy. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Malignant gastric outlet obstruction (GOO) occurs with advanced or metastatic malignancies located in the duodenum and is present in up to 19% of patients with unresectable malignant tumors [ 1 ]. Duodenal obstruction can be traditionally treated by gastrojejunostomy, but endoscopic duodenal stenting has been suggested as a less invasive treatment [ 2 ]. More recently, endoscopic ultrasound-guided gastroenterostomy using lumen-apposing metal stents has been reported [ 3 ] [ 4 ]. However, as this technique may need to be performed by experts or in high-volume centers, endoscopic duodenal stenting is still an important procedure. During duodenal stenting, guidewire passage through the stricture to the anal side is needed, but this technique is sometimes challenging. Recently, a novel cholangioscope (eyeMAX; Micro-Tech Co., Ltd., Nanjing, China), which offers improved visibility, has become available. This report describes guidewire deployment using this novel cholangioscope for guidance in duodenal stent deployment in a case of duodenal obstruction. A 58-year-old man was admitted to our hospital with GOO caused by cancer of the head of the pancreas. This patient had previously undergone biliary drainage using a covered self-expandable metal stent (SEMS). Duodenal stenting was attempted. First, the duodenoscope was advanced into the ampulla of Vater. However, because of the SEMS, the duodenal obstruction site could not be observed endoscopically. Therefore, an endoscopic retrograde cholangiopancreatography catheter was inserted ([ Fig. 1 ]), and guidewire insertion through the obstruction site was attempted; however, guidewire insertion failed ([ Fig. 2 ]). A novel cholangioscope was then inserted, and the obstruction site could be observed clearly ([ Fig. 3 ]). Guidewire insertion was performed successfully under direct visualization ([ Fig. 4 ]). After duodenography, duodenal metal stent deployment was performed successfully without any adverse events ([ Fig. 5 ], [ Video 1 ]). Fig. 1 An endoscopic retrograde cholangiopancreatography catheter was inserted because the duodenal obstruction site could not be seen owing to the presence of the biliary stent. Fig. 2 Guidewire insertion failed under fluoroscopic guidance. Fig. 3 The duodenal obstruction site could be seen clearly with the novel cholangioscope. Fig. 4 Guidewire insertion was performed successfully. Fig. 5 Duodenal stenting was performed successfully. Download Video Guidewire insertion through the duodenal obstruction site was attempted but failed. A novel cholangioscope was inserted, and the obstruction site was observed. Guidewire insertion and duodenal stenting were performed successfully.Video 1 In conclusion, a novel cholangioscope may be useful not only for biliary disease, but also for guidewire insertion under direct visualization, thanks to improved visibility. Endoscopy_UCTN_Code_CCL_1AB_2AZ_3AB Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos . Publication History Article published online: 20 November 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Endoscopy Center, Osaka Medical and Pharmaceutical University, Takatsuki, Japan.
- 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Japan.
Zitieren
APA
Ogura, T., Nakamura, J., Sakamoto, J., Uba, Y., & Nishikawa, H. (2023). Duodenal metal stent deployment using a novel, cholangioscope-guided, guidewire insertion technique. Endoscopy, 55(S 01 S 01), E1154-E1155. https://doi.org/10.1055/a-2183-6315
Vancouver
Ogura T, Nakamura J, Sakamoto J, Uba Y, Nishikawa H. Duodenal metal stent deployment using a novel, cholangioscope-guided, guidewire insertion technique. Endoscopy. 2023;55(S 01 S 01):E1154-E1155. doi:10.1055/a-2183-6315
BibTeX
@article{Ogura2023,
author = {Ogura, Takeshi and Nakamura, Junichi and Sakamoto, Jun and Uba, Yuki and Nishikawa, Hiroki},
title = {Duodenal metal stent deployment using a novel, cholangioscope-guided, guidewire insertion technique},
journal = {Endoscopy},
year = {2023},
volume = {55},
number = {S 01 S 01},
pages = {E1154--E1155},
doi = {10.1055/a-2183-6315}
}
EUVIMED