Novel Umbilical Catheter Securement and Protection Device for Umbilical Line Securement during Laparotomy
American Journal of Perinatology · 01.05.2024 · 41 (S 01 S 01) · e2901-e2906
DOI: 10.1055/a-2182-4221 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von Fereshteh Salimi-Jazi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pediatric Surgery, Department of Surgery, Stanford University, California. Hauptthemen laut MEDLINE: Laparotomy, Umbilical Veins. Die Arbeit nennt 14 Literaturangaben.
Abstract (Originalsprache)
Objective
Umbilical catheter malposition rate is high. We compared a Novel Umbilical Securement Device (NUSD) to standard methodologies for neonatal invasive care unit patients undergoing laparotomy. Study Design Retrospective study was performed on infants undergoing laparotomy from April 2019 to January 2023. Two neonatologists compared position of umbilical arterial catheter/umbilical venous catheter (UVC) on perioperative chest X-ray (CXRs) in patients with or without NUSD.
Results
Eighteen patients underwent laparotomy, of which 8 patients had NUSD (9 lines) and 10 patients did not (14 lines). In NUSD group, mean gestational age was 37 ± 4 weeks and mean birth weight was 2.3 ± 0.9 kg compared with 31 ± 8 weeks and 2.1 ± 1.4 kg in non-NUSD group, respectively. The mean age at surgery was 5 ± 7 and 5 ± 3 days, respectively. No malposition was seen in NUSD group, while 57% of UVCs (28% of lines) were malpositioned postoperatively in non-NUSD group (p = 0.048).
Conclusion
NUSD is an umbilical catheter securement device with low malposition rate, specifically during perioperative period with heightened risk for dislodgement. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Pediatric Surgery, Department of Surgery, Stanford University, California.
- Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford University, California.
Zitieren
APA
Salimi-Jazi, F., Wood, L., Rafeeqi, T., Yamada, N., Fuerch, J., & Wall, J. (2024). Novel Umbilical Catheter Securement and Protection Device for Umbilical Line Securement during Laparotomy. American Journal of Perinatology, 41(S 01 S 01), e2901-e2906. https://doi.org/10.1055/a-2182-4221
Vancouver
Salimi-Jazi F, Wood L, Rafeeqi T, Yamada N, Fuerch J, Wall J. Novel Umbilical Catheter Securement and Protection Device for Umbilical Line Securement during Laparotomy. American Journal of Perinatology. 2024;41(S 01 S 01):e2901-e2906. doi:10.1055/a-2182-4221
BibTeX
@article{SalimiJazi2024,
author = {Salimi-Jazi, Fereshteh and Wood, Lauren and Rafeeqi, Talha and Yamada, Nicole and Fuerch, Janene and Wall, James},
title = {Novel Umbilical Catheter Securement and Protection Device for Umbilical Line Securement during Laparotomy},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {S 01 S 01},
pages = {e2901--e2906},
doi = {10.1055/a-2182-4221}
}