Correct and Incorrect Recommendations for or against Fine Needle Biopsies of Hypofunctioning Thyroid Nodules: Performance of Different Ultrasound-based Risk Stratification Systems
Nuklearmedizin - NuclearMedicine · 01.02.2024 · 63 (01) · 21-33
DOI: 10.1055/a-2178-6739 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Nuklearmedizin - NuclearMedicine, erschienen am 01.02.2024. Verfasst von Manuela Petersen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of General, Visceral, Vascular and Transplant Surgery, University Hospital Magdeburg, Germany. Hauptthemen laut MEDLINE: Thyroid Nodule, Thyroid Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate the recommendations for or against fine needle biopsy (FNB) of hypofunctioning thyroid nodules (TNs) using of five different Ultrasound (US) -based risk stratification systems (RSSs).
Methods
German multicenter study with 563 TNs (≥ 10 mm) in 534 patients who underwent thyroid US and surgery. All TNs were evaluated with ACR TI-RADS, EU-TIRADS, ATA, K-TIRADS 2016 and modified K-TIRADS 2021. A correct recommendation was defined as: malignant TN with recommendation for FNB (appropriate) or benign TN without recommendation for FNB (avoided). An incorrect recommendation was defined as: malignant TN without recommendation for FNB (missed) or benign TN with recommendation for FNB (unnecessary).
Results
ACR TI-RADS demonstrated the highest rate of correct (42.3 %) and lowest rate of incorrect recommendations (57.7 %). The other RRSs showed similar results for correct (26.5 %–35.7 %) and incorrect (64.3 %–73.5 %) recommendations. ACR TI-RADS demonstrated the lowest rate of unnecessary (73.4 %) and the highest rate of appropriate (26.6 %) FNB recommendation. For other RSSs, the rates of unnecessary and appropriate FNB were between 75.2 %–77.1 % and 22.9 %–24.8 %. The lowest rate of missed FNB (14.7 %) and the highest rate of avoided FNB (85.3 %) was found for ACR TI-RADS. For the other RSSs, the rates of missed and avoided FNB were between 17.8 %–26.9 % and 73.1 %–82.2 %. When the size cutoff was disregarded, an increase of correct recommendations and a decrease of incorrect recommendations was observed for all RSSs.
Conclusion
The RSSs vary in their ability to correctly recommend for or against FNB. An understanding of the impact of nodule size cutoffs seems necessary for the future of TIRADS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of General, Visceral, Vascular and Transplant Surgery, University Hospital Magdeburg, Germany.
- Department and Institute of Nuclear Medicine, Hospital Bayreuth, Germany.
- Division of Nuclear Medicine, Department of Radiology and Nuclear Medicine, University Hospital Magdeburg, Germany.
- Clinic of Nuclear Medicine, University Hospital Jena, Germany.
- Clinic for Nuclear Medicine, University Hospital Essen, Germany.
- Department of Nuclear Medicine, German Armed Forces Hospital Ulm, Germany.
Zitieren
APA
Petersen, M., Schenke, S. A., Seifert, P., Stahl, A. R., Görges, R., Grunert, M., Klemenz, B., Kreissl, M. C., & Zimny, M. (2024). Correct and Incorrect Recommendations for or against Fine Needle Biopsies of Hypofunctioning Thyroid Nodules: Performance of Different Ultrasound-based Risk Stratification Systems. Nuklearmedizin - NuclearMedicine, 63(01), 21-33. https://doi.org/10.1055/a-2178-6739
Vancouver
Petersen M, Schenke SA, Seifert P, Stahl AR, Görges R, Grunert M, et al. Correct and Incorrect Recommendations for or against Fine Needle Biopsies of Hypofunctioning Thyroid Nodules: Performance of Different Ultrasound-based Risk Stratification Systems. Nuklearmedizin - NuclearMedicine. 2024;63(01):21-33. doi:10.1055/a-2178-6739
BibTeX
@article{Petersen2024,
author = {Petersen, Manuela and Schenke, Simone A and Seifert, Philipp and Stahl, Alexander R and Görges, Rainer and Grunert, Michael and Klemenz, Burkhard and Kreissl, Michael C and Zimny, Michael},
title = {Correct and Incorrect Recommendations for or against Fine Needle Biopsies of Hypofunctioning Thyroid Nodules: Performance of Different Ultrasound-based Risk Stratification Systems},
journal = {Nuklearmedizin - NuclearMedicine},
year = {2024},
volume = {63},
number = {01},
pages = {21--33},
doi = {10.1055/a-2178-6739}
}
EUVIMED