Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.10.2024. Verfasst von Nobuyuki Yoshiyasu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Surgery, St. Luke's International Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Lung Neoplasms, Predictive Value of Tests, Adenocarcinoma of Lung, Tomography, X-Ray Computed. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
Background
Nondisappearing subsolid nodules requiring follow-up are often detected during lung cancer screening, but changes in their invasiveness can be overlooked owing to slow growth. We aimed to develop a method for automatic identification of invasive tumors among subsolid nodules during multiple health checkups using radiomics technology based on low-dose computed tomography (LD-CT) and examine its effectiveness.
Methods
We examined patients who underwent LD-CT screening from 2014 to 2019 and had lung adenocarcinomas resected after 5-year follow-ups. They were categorized into the invasive or less-invasive group; the annual growth/change rate (Δ) of the nodule voxel histogram using three-dimensional CT (e.g., tumor volume, solid volume percentage, mean CT value, variance, kurtosis, skewness, and entropy) was assessed. A discriminant model was designed through multivariate regression analysis with internal validation to compare its efficacy with that of a volume doubling time of < 400 days.
Results
The study included 47 tumors (23 invasive, 24 less invasive), with no significant difference in the initial tumor volumes. Δskewness was identified as an independent predictor of invasiveness (adjusted odds ratio, 0.021; p = 0.043), and when combined with Δvariance, it yielded high accuracy in detecting invasive lesions (88% true-positive, 80% false-positive). The detection model indicated surgery 2 years earlier than the volume doubling time, maintaining accuracy (median 3 years vs.1 year before actual surgery, p = 0.011).
Conclusion
LD-CT radiomics showed promising potential in ensuring timely detection and monitoring of subsolid nodules that warrant follow-up over time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Thoracic Surgery, St. Luke's International Hospital, Tokyo, Japan.
- Graduate School of Public Health, St. Luke's International University, Tokyo, Japan.
- Department of Radiology, St. Luke's International Hospital, Tokyo, Japan.
ORCID-Profile: Nobuyuki Yoshiyasu, Fumitsugu Kojima
Zitieren
APA
Yoshiyasu, N., Kojima, F., Hayashi, K., Yamada, D., & Bando, T. (2024). Low-Dose CT Screening of Persistent Subsolid Lung Nodules: First-Order Features in Radiomics. The Thoracic and Cardiovascular Surgeon, 72(07), 542-549. https://doi.org/10.1055/a-2158-1364
Vancouver
Yoshiyasu N, Kojima F, Hayashi K, Yamada D, Bando T. Low-Dose CT Screening of Persistent Subsolid Lung Nodules: First-Order Features in Radiomics. The Thoracic and Cardiovascular Surgeon. 2024;72(07):542-549. doi:10.1055/a-2158-1364
BibTeX
@article{Yoshiyasu2024,
author = {Yoshiyasu, Nobuyuki and Kojima, Fumitsugu and Hayashi, Kuniyoshi and Yamada, Daisuke and Bando, Toru},
title = {Low-Dose CT Screening of Persistent Subsolid Lung Nodules: First-Order Features in Radiomics},
journal = {The Thoracic and Cardiovascular Surgeon},
year = {2024},
volume = {72},
number = {07},
pages = {542--549},
doi = {10.1055/a-2158-1364}
}
EUVIMED