Success rates of fixation techniques on prevention of esophageal stent migration: a systematic review and meta-analysis
Endoscopy · 01.01.2024 · 56 (01) · 22-30
DOI: 10.1055/a-2147-8294 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Endoscopy, erschienen am 01.01.2024. Verfasst von Apostolis Papaefthymiou und 10 weiteren Autor:innen. Beteiligte Einrichtung: Endoscopy Unit, University College London Hospitals, London, United Kingdom. Hauptthemen laut MEDLINE: Stents, Deglutition Disorders. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
Background
Esophageal stenting is an important intervention for managing malignant and benign dysphagia, with stent migration representing a common drawback. This systematic review with meta-analysis aimed to assess the benefit of stent fixation over nonfixation.
Methods
A systematic search was performed in MEDLINE, Cochrane, Scopus, and ClinicalTrials.gov databases until January 2023 for comparative studies evaluating the migration rates of esophageal stents with versus without (control) fixation. The primary outcome was migration rate. Secondary outcomes included adverse event rate. A subgroup analysis stratified the results based on different fixation techniques: suturing, over-the-scope (OTS) clipping, and through-the-scope (TTS) clipping. Meta-analysis was based on a random effects model and the results were reported as odds ratios (ORs) with 95 %CIs.
Results
10 studies (1014 patients) were included. The rate of stent migration was significantly lower after fixation (OR 0.20, 95 %CI 0.11–0.37; I2 = 59 %, P = 0.01). The adverse event rate was similar between fixation and control groups (OR 0.65, 95 %CI 0.28–1.52; I2 = 55 %, P = 0.06). In the subgroup analysis, all fixation techniques remained superior to nonfixation of stents (suturing OR 0.23, 95 %CI 0.10–0.53; OTS clips OR 0.31, 95 %CI 0.17–0.58; TTS clips OR 0.10, 95 %CI 0.03–0.38); however, only the OTS and TTS clip groups achieved nonsignificant heterogeneity (I2 = 0 %, P = 0.67 and P = 0.73, respectively). No difference between techniques was recorded for migration rates.
Conclusion
Esophageal stent fixation was associated with significantly lower migration rates compared with nonfixation of stents, regardless of fixation technique and stenting indication.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Endoscopy Unit, University College London Hospitals, London, United Kingdom.
- Department of Gastroenterology, General Hospital of Nea Ionia "Konstantopoulio-Patision", Athens, Greece.
- Department of Gastroenterology, Hepatopancreatology and Digestive Oncology, Erasme University Hospital, Université Libre de Bruxelles, Brussels, Belgium.
- Gastroenterology and Hepatology, University of Utah Health, Salt Lake City, Utah, United States.
- Cleveland Clinic London, London, United Kingdom.
ORCID-Profile: Apostolis Papaefthymiou, Georgios Tziatzios, Benjamin Norton
Zitieren
APA
Papaefthymiou, A., Gkolfakis, P., Basiliya, K., Ramai, D., Tziatzios, G., Sehgal, V., Telese, A., Norton, B., Aslam, N., Johnson, G., & Haidry, R. (2024). Success rates of fixation techniques on prevention of esophageal stent migration: a systematic review and meta-analysis. Endoscopy, 56(01), 22-30. https://doi.org/10.1055/a-2147-8294
Vancouver
Papaefthymiou A, Gkolfakis P, Basiliya K, Ramai D, Tziatzios G, Sehgal V, et al. Success rates of fixation techniques on prevention of esophageal stent migration: a systematic review and meta-analysis. Endoscopy. 2024;56(01):22-30. doi:10.1055/a-2147-8294
BibTeX
@article{Papaefthymiou2024,
author = {Papaefthymiou, Apostolis and Gkolfakis, Paraskevas and Basiliya, Kirill and Ramai, Daryl and Tziatzios, Georgios and Sehgal, Vinay and Telese, Andrea and Norton, Benjamin and Aslam, Nasar and Johnson, Gavin and Haidry, Rehan},
title = {Success rates of fixation techniques on prevention of esophageal stent migration: a systematic review and meta-analysis},
journal = {Endoscopy},
year = {2024},
volume = {56},
number = {01},
pages = {22--30},
doi = {10.1055/a-2147-8294}
}