Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von C Andrew Combs und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pediatrix Center for Research, Education, Quality and Safety, Pediatrix Medical Group, Sunrise, Florida. Hauptthemen laut MEDLINE: Ultrasonography, Prenatal, Head, Fetal Development, Cephalometry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
Objective
This study aimed to evaluate which of five established norms should be used for sonographic assessment of fetal head circumference (HC). Study Design Cross-sectional study using pooled data from four maternal–fetal medicine practices. Inclusion criteria were singleton fetus, gestational age 220/7 to 396/7 weeks, biometry measured, and fetal cardiac activity present. Five norms of HC were studied: Jeanty et al, Hadlock et al, the INTERGROWTH-21st Project (IG-21st), the World Health Organization Fetal Growth Curves (WHO), and the National Institutes of Child Health and Human Development Fetal Growth Studies unified standard (NICHD-U). The fit of our HC measurements to each norm was assessed by these criteria: mean z-score close to 0, standard deviation (SD) of z close to 1, low Kolmogorov–Smirnov D-statistic, high Youden J-statistic, close to 10% of exams >90th percentile, close to 10% of exams 2 SD below the mean.
Results
In 23,565 ultrasound exams, our HC measurements had the best fit to the WHO standard (mean z-score 0.10, SD of z = 1.01, D-statistic
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Pediatrix Center for Research, Education, Quality and Safety, Pediatrix Medical Group, Sunrise, Florida.
- Obstetrix of San Jose, Campbell, California.
- Obstetrix Maternal-Fetal Medicine Specialists, Houston, Texas.
- Perinatal Associates of Sacramento, Sacramento, California.
- Eastside Maternal-Fetal Medicine Specialists, Bellevue, Washington.
Zitieren
APA
Combs, C. A., Rosario, A. D., Balogun, O. A., Bowman, Z. S., & Amara, S. (2024). Selection of Standards for Sonographic Fetal Head Circumference by Use of z-Scores. American Journal of Perinatology, 41(S 01 S 01), e2625-e2635. https://doi.org/10.1055/a-2135-6838
Vancouver
Combs CA, Rosario AD, Balogun OA, Bowman ZS, Amara S. Selection of Standards for Sonographic Fetal Head Circumference by Use of z-Scores. American Journal of Perinatology. 2024;41(S 01 S 01):e2625-e2635. doi:10.1055/a-2135-6838
BibTeX
@article{Combs2024,
author = {Combs, C Andrew and Rosario, Amber Del and Balogun, Olaide Ashimi and Bowman, Zachary S and Amara, Sushma},
title = {Selection of Standards for Sonographic Fetal Head Circumference by Use of z-Scores},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {S 01 S 01},
pages = {e2625--e2635},
doi = {10.1055/a-2135-6838}
}
EUVIMED