Piercing technique for mucosal hyperplasia at an uncovered part of a partially covered stent after endoscopic ultrasound-guided hepaticogastrostomy
Endoscopy International Open · 01.09.2023 · 11 (09) · E811-E813
DOI: 10.1055/a-2132-5116 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 01.09.2023. Verfasst von Yasuo Otsuka und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A partially covered self-expandable metal stent (PCSEMS) is preferred in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) to prevent stent dislocation and branch duct occlusion [ 1 ] [ 2 ]. A PCSEMS with a 10-mm uncovered part on the proximal end (Modified Giobor Stent; Taewoong Medical, Seoul) ([ Fig. 1 ]a) has been used frequently [ 2 ] [ 3 ]; however, tissue hyperplasia occurs around the uncovered part, leading to recurrent biliary obstruction (RBO) [ 2 ] [ 3 ]. RBO due to hyperplasia is sometimes hardened with abundant fibrosis, resulting in failed guidewire passage during endoscopic reintervention [ 3 ] [ 4 ]. Here, we present a novel technique to regain biliary access after EUS-HGS with subsequent hyperplasia with the uncovered portion of the PCSEMS. Fig. 1 a A partially covered self-expandable metal stent (Modified Giobor Stent; Taewoong Medical, Seoul, South Korea) made of braided nitinol wire partially covered by a silicone membrane. The proximal end has a 10-mm uncovered portion. b Endoscopic view of the partially covered metal stent in the gastric lumen after endoscopic ultrasound-guided hepaticogastrostomy. A 67-year-old male with a history of distal gastrectomy with Roux-en-Y reconstruction was admitted due to jaundice. The patient had undergone EUS-HGS with the PCSEMS for biliary obstruction due to lymph node metastasis 8 months before admission ([ Fig. 1 ]b). To relieve jaundice, reintervention via the distal end of the PCSEMS was performed. A cannulation catheter was inserted from the distal end of the PCSEMS, but a 0.035-inch guidewire (Jagwire; Boston Scientific, Natick, Massachusetts, United States) could not be advanced beyond the PCSEMS. The uncovered part of the PCSEMS was not imaged by contrast medium injection, indicating a complete RBO due to hyperplasia ([ Fig. 2 ]). Next, a stone extraction balloon was inflated inside the PCSEMS to allow passage of the guidewire through the center of the PCSEMS ([ Fig. 3 ]). However, the hyperplasia was too stiff. Finally, a “piercing technique” using the stiff back end of the guidewire [ 5 ] was performed, which allowed the guidewire to smoothly advance the stricture ([ Fig. 4 ], [ Video 1 ]). After dilating the uncovered part with an 8-mm balloon dilator, a dedicated plastic stent was successfully deployed through the PCSEMS ([ Fig. 5 ]). The patient’s jaundice resolved after endoscopic revision and was discharged 6 days after admission. Fig. 2 The uncovered part of the partially covered metal tent was not imaged by contrast medium injection (arrowheads), indicating a complete recurrent biliary obstruction due to hyperplasia. Fig. 3 A stone extraction balloon (Fusion Extraction Balloon; Cook Medical, Bloomington, Indiana, United States) was inflated inside the partially covered metal stent to allow passage of the guidewire through the center of the stent ( a fluoroscopic view, b. diagram). Fig. 4 In a “piercing technique,” the stiff back end of a 0.035-inch guidewire (Jagwire; Boston Scientific, Natick, Massachusetts, United States) was used, which enabled the smooth advancement of the guidewire beyond the hyperplasia at the proximal end of the stent ( a fluoroscopic view, b diagram). Fig. 5 A dedicated 7F × 14-cm plastic stent (TYPE-IT Stent; Gadelius Medical, Tokyo, Japan) was successfully deployed through the existing partially covered metal stent ( a fluoroscopic view, b endoscopic view). Download Video Endoscopic reintervention using a “piercing technique” for mucosal hyperplasia after endoscopic ultrasound-guided hepaticogastrostomy.Video 1 Publication History Received: 30 April 2023 Accepted after revision: 02 June 2023 Article published online: 01 September 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan.
ORCID-Profile: Kosuke Minaga, Mamoru Takenaka
Zitieren
APA
Otsuka, Y., Minaga, K., Hara, A., Masuta, Y., Takenaka, M., & Kudo, M. (2023). Piercing technique for mucosal hyperplasia at an uncovered part of a partially covered stent after endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy International Open, 11(09), E811-E813. https://doi.org/10.1055/a-2132-5116
Vancouver
Otsuka Y, Minaga K, Hara A, Masuta Y, Takenaka M, Kudo M. Piercing technique for mucosal hyperplasia at an uncovered part of a partially covered stent after endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy International Open. 2023;11(09):E811-E813. doi:10.1055/a-2132-5116
BibTeX
@article{Otsuka2023,
author = {Otsuka, Yasuo and Minaga, Kosuke and Hara, Akane and Masuta, Yasuhiro and Takenaka, Mamoru and Kudo, Masatoshi},
title = {Piercing technique for mucosal hyperplasia at an uncovered part of a partially covered stent after endoscopic ultrasound-guided hepaticogastrostomy},
journal = {Endoscopy International Open},
year = {2023},
volume = {11},
number = {09},
pages = {E811--E813},
doi = {10.1055/a-2132-5116}
}
EUVIMED