Cold snare endoscopic mucosal resection for colon polyps: a systematic review and meta-analysis
Endoscopy · 2023-12 · 55 (12) · 1083-1094
DOI: 10.1055/a-2129-5752 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Endoscopy, online erschienen am 22.09.2023. Verfasst von Mohamed Abdallah und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Gastroenterology, Hepatology, and Nutrition, University of Minnesota, Minneapolis, Minnesota, United States. Hauptthemen laut MEDLINE: Colonic Polyps, Endoscopic Mucosal Resection, Adenoma, Colorectal Neoplasms. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
Background
Cold snare endoscopic mucosal resection (CS-EMR) can reduce the risks associated with electrocautery during colon polyp resection. Data on efficacy are variable. This systematic review and meta-analysis aimed to estimate the pooled efficacy and safety rates of CS-EMR.
Methods
We conducted a comprehensive literature search of multiple databases, from inception to March 2023, for studies addressing outcomes of CS-EMR for colon polyps. The weighted pooled estimates with 95 %CIs were calculated using the random effects model. I2 statistics were used to evaluate heterogeneity.
Results
4137 articles were reviewed, and 16 studies, including 2592 polyps in 1922 patients (51.4 % female), were included. Overall, 54.4 % of polyps were adenomas, 45 % were sessile serrated lesions (SSLs), and 0.6 % were invasive carcinomas. Polyp recurrence after CS-EMR was 6.7 % (95 %CI 2.4 %–17.4 %, I2 = 94 %). The recurrence rate was 12.3 % (95 %CI 3.4 %–35.7 %, I2 = 94 %) for polyps ≥ 20 mm, 17.1 % (95 %CI 4.6 %–46.7 %, I2 = 93 %) for adenomas, and 5.7 % (95 %CI 3.2 %–9.9 %, I2 = 50 %) for SSLs. The pooled intraprocedural bleeding rate was 2.6 % (95 %CI 1.5 %–4.5 %, I2 = 51 %), the delayed bleeding rate was 1.5 % (95 %CI 0.8 %–2.7 %, I2 = 18 %), and no perforations or post-polypectomy syndromes were reported, with estimated rates of 0.6 % (95 %CI 0.3 %–1.3 %, I2 = 0 %) and 0.6 % (95 %CI 0.3 %–1.4 %, I2 = 0 %), respectively.
Conclusion
CS-EMR demonstrated an excellent safety profile for colon polyps, with variable recurrence rates based on polyp size and histology. Large prospective studies are needed to validate these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medicine, Division of Gastroenterology, Hepatology, and Nutrition, University of Minnesota, Minneapolis, Minnesota, United States.
- Department of Internal Medicine, The Wright Center for Graduate Medical Education, Scranton, Pennsylvania, United States.
- Department of Internal Medicine, East Carolina University, Greenville, North Carolina, United States.
- Brown University, Warren Alpert Medical School, Providence, Rhode Island, United States.
- Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, United States.
- Division of Gastroenterology, Department of Medicine and Population Health, NYU Grossman School of Medicine, New York, New York, United States.
ORCID-Profile: Mouhand F H Mohamed
Zitieren
APA
Abdallah, M., Ahmed, K., Abbas, D., Mohamed, M. F. H., Suryawanshi, G., McDonald, N., Wilson, N., Umar, S., Shaukat, A., & Bilal, M. (2023). Cold snare endoscopic mucosal resection for colon polyps: a systematic review and meta-analysis. Endoscopy, 55(12), 1083-1094. https://doi.org/10.1055/a-2129-5752
Vancouver
Abdallah M, Ahmed K, Abbas D, Mohamed MFH, Suryawanshi G, McDonald N, et al. Cold snare endoscopic mucosal resection for colon polyps: a systematic review and meta-analysis. Endoscopy. 2023;55(12):1083-1094. doi:10.1055/a-2129-5752
BibTeX
@article{Abdallah2023,
author = {Abdallah, Mohamed and Ahmed, Khalid and Abbas, Daniyal and Mohamed, Mouhand F H and Suryawanshi, Gaurav and McDonald, Nicholas and Wilson, Natalie and Umar, Shifa and Shaukat, Aasma and Bilal, Mohammad},
title = {Cold snare endoscopic mucosal resection for colon polyps: a systematic review and meta-analysis},
journal = {Endoscopy},
year = {2023},
volume = {55},
number = {12},
pages = {1083--1094},
doi = {10.1055/a-2129-5752}
}