EUVIMEDEUVIMED entdecken
Crossref

Can We Do Anything Else before Removing a Button Battery from the Esophagus?—Hyaluronic Acid

I Bada-Bosch iD, M D Blanco Verdú, J A Cerdá, M Fanjul, J Ordoñez iD, M M Tolín Hernani, C Miranda Cid, C Sánchez Sánchez, J C De Agustín

European Journal of Pediatric Surgery · 01.02.2024 · 34 (01) · 056-062

DOI: 10.1055/a-2123-5214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Pediatric Surgery, erschienen am 01.02.2024. Verfasst von I Bada-Bosch und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatric Surgery, Hospital Universitario Gregorio Marañón, Madrid, Spain. Hauptthemen laut MEDLINE: Hyaluronic Acid, Foreign Bodies. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This article tests the protective effect of a commercially available mixture of hyaluronic acid, chondroitin sulfate, and poloxamer 407 on the damage caused by the exposure of esophageal mucosa to button batteries in an animal model.

Methods

Experimental study. Sixty porcine esophageal samples were distributed in three groups: control (CG), exposure (EG), and exposure-protection (EPG). In EG and EPG, one CR2032 button battery per sample was inserted, both were subdivided into 2-, 4-, 6-, and 24-hour exposure subgroups, with subsequent battery removal. EPG samples were irrigated with the solution 1 hour after battery exposure. Esophageal pH and final voltage of the battery were measured. Results pH in CG remained stable. No significant differences in pH at 1 hour were found between EG and EPG. In EPG, the pH of the mucosa exposed to the anode was lower than in GE at 2 hours (12.44 vs. 11.89, p = 0.203) and 4 hours (13.78 vs. 11.77, p < 0.0001). In the cathode pH was significantly higher in EG at 2 hours (2.5 vs. 4.11, p < 0.0001), 4 hours (2.33 vs. 4.78, p < 0.0001), and 6 hours (2.17 vs. 2.91, p < 0.0001). Significant voltage reduction at 1 hour was found in EG compared to EPG (0.48 vs. 1.08 V, p = 0.004).

Conclusion

Exposure to hyaluronic acid solution buffers the acidification on the side exposed to the cathode and basification on the anode. This effect can be maintained up to 3 to 5 hours, even after stopping its application. Our results suggest that a solution containing hyaluronic acid could be used as an esophageal protector after accidental ingestion of button batteries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hyaluronic AcidForeign BodiesAnimalsSwineEsophagusElectric Power Supplies

Substanzen

Hyaluronic Acid

Autor:innen und Institutionen

  • Department of Pediatric Surgery, Hospital Universitario Gregorio Marañón, Madrid, Spain.
  • Department of Pediatric Gastroenterology, Hepatology and Nutrition, Hospital Universitario Gregorio Marañón, Madrid, Spain.

ORCID-Profile: I Bada-Bosch, J Ordoñez

Zitieren

APA

Bada-Bosch, I., Blanco Verdú, M. D., Cerdá, J. A., Fanjul, M., Ordoñez, J., Tolín Hernani, M. M., Miranda Cid, C., Sánchez Sánchez, C., & De Agustín, J. C. (2024). Can We Do Anything Else before Removing a Button Battery from the Esophagus?—Hyaluronic Acid. European Journal of Pediatric Surgery, 34(01), 056-062. https://doi.org/10.1055/a-2123-5214

Vancouver

Bada-Bosch I, Blanco Verdú MD, Cerdá JA, Fanjul M, Ordoñez J, Tolín Hernani MM, et al. Can We Do Anything Else before Removing a Button Battery from the Esophagus?—Hyaluronic Acid. European Journal of Pediatric Surgery. 2024;34(01):056-062. doi:10.1055/a-2123-5214

BibTeX
@article{BadaBosch2024,
  author = {Bada-Bosch, I and Blanco Verdú, M D and Cerdá, J A and Fanjul, M and Ordoñez, J and Tolín Hernani, M M and Miranda Cid, C and Sánchez Sánchez, C and De Agustín, J C},