Description of Standardized Planes and Angles for Percutaneous Supra-acetabular Screw Placement
Zeitschrift für Orthopädie und Unfallchirurgie · 01.08.2024 · 162 (04) · 419-425
DOI: 10.1055/a-2107-0948 ↗Kurz gefasst
Fachartikel in der Zeitschrift Zeitschrift für Orthopädie und Unfallchirurgie, erschienen am 01.08.2024. Verfasst von Julian Rüwald und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care Medicine, Essen, Germany, University Hospital Essen, Essen, Germany. Hauptthemen laut MEDLINE: Bone Screws, Fracture Fixation, Internal, Fractures, Bone, Pelvic Bones. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
Percutaneous screw fixation for pelvic fractures has become a minimally invasive alternative to an open operation. The complex anatomy of the pelvis renders this procedure challenging. The objective of this study was to assess standardized angles and dimensions of safety zones within a 3 D computed tomography model for optimal supra-acetabular screw placement.
Methods
Computed tomography scans of 107 patients that suffered major trauma without showing any bone injury of the pelvis were collected. Using a software-based analysis, raw computed tomography data were transformed into 3 D models to set standardized landmarks and determine the possible insertion corridor.
Results
Screws not exceeding a length of 97 mm in females and 106.4 mm in males were, in 95% of the evaluated cases, insertable without cortical bone penetration. The safety zone was 6.6 mm for females and 7.9 mm for males. Screws not exceeding these diameters were safely insertable in 95% of the cases. For the midsagittal plane, the angle was 36.4 ± 5.1 on the left and 34.7 ± 2.9 on the right (p = 0.008). For the anterior pelvic plane, the angle was 31.3 ± 4.5° on the left and 34.0 ± 4.8° on the right (p = 0.008).
Conclusions
Percutaneous fixation using supra-acetabular screws is a promising method to treat simple supra-acetabular fractures. These results may improve its safe utilization and could facilitate its broader clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Anesthesiology and Intensive Care Medicine, Essen, Germany, University Hospital Essen, Essen, Germany.
- Department for Orthopaedics and Trauma Surgery, University Hospital Bonn, Bonn, Germany.
- Institute for Medical Microbiology, Immunology and Parasitology, University Hospital Bonn, Bonn, Germany.
ORCID-Profile: Martin Gathen, Koroush Kabir
Zitieren
APA
Rüwald, J., Ploeger, M. M., Hischebeth, G. T., Tüllmann, M., Roos, J., Gathen, M., & Kabir, K. (2024). Description of Standardized Planes and Angles for Percutaneous Supra-acetabular Screw Placement. Zeitschrift für Orthopädie und Unfallchirurgie, 162(04), 419-425. https://doi.org/10.1055/a-2107-0948
Vancouver
Rüwald J, Ploeger MM, Hischebeth GT, Tüllmann M, Roos J, Gathen M, et al. Description of Standardized Planes and Angles for Percutaneous Supra-acetabular Screw Placement. Zeitschrift für Orthopädie und Unfallchirurgie. 2024;162(04):419-425. doi:10.1055/a-2107-0948
BibTeX
@article{Rwald2024,
author = {Rüwald, Julian and Ploeger, Milena Maria and Hischebeth, Gunnar T and Tüllmann, Mareike and Roos, Jonas and Gathen, Martin and Kabir, Koroush},
title = {Description of Standardized Planes and Angles for Percutaneous Supra-acetabular Screw Placement},
journal = {Zeitschrift für Orthopädie und Unfallchirurgie},
year = {2024},
volume = {162},
number = {04},
pages = {419--425},
doi = {10.1055/a-2107-0948}
}
EUVIMED