The Accuracy of a Portable Accelerometer-Based Navigation System for Tibial Alignment Can be Reliable during Total Knee Arthroplasty for Obese Patients
The Journal of Knee Surgery · 01.03.2024 · 37 (04) · 303-309
DOI: 10.1055/a-2094-8822 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Knee Surgery, erschienen am 01.03.2024. Verfasst von Kazumi Goto und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Mitsui Memorial Hospital, Chiyoda-ku, Tokyo, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Surgery, Computer-Assisted, Osteoarthritis, Knee. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
A portable accelerometer-based navigation system can be useful for achieving the target alignment. Tibial registration is based on the medial and lateral malleoli; however, the identification of landmarks may be difficult in obese (body mass index [BMI] >30 kg/m2) patients whose bones are not easily palpable from the body surface. This study compared tibial component alignment achieved using a portable accelerometer-based navigation system (Knee Align 2 [KA2]) in obese and control groups and aimed to validate the accuracy of bone cutting in obese patients. A total of 210 knees that underwent primary total knee arthroplasty using the KA2 system were included. After 1:3 propensity score matching, there were 32 and 96 knees in the BMI >30 group (group O) and BMI ≤30 group (group C), respectively. The absolute deviations of the tibial implant from the intended alignment were evaluated in the coronal plane (hip–knee–ankle [HKA] angle and medial proximal tibial angle) and sagittal plane (posterior tibial slope [PTS]). The inlier rate of each cohort, which was defined as tibial component alignment within 2 degrees of the intended alignment, was investigated. In the coronal plane, the absolute deviations of the HKA and MPTA from the intended alignment were 2.2 ± 1.8 degrees and 1.8 ± 1.5 degrees in group C and 1.7 ± 1.5 degrees and 1.7 ± 1.0 degrees in group O (p = 1.26, and p = 0.532). In the sagittal plane, the absolute deviations of the tibial implant were 1.6 ± 1.2 degrees in group C and 1.5 ± 1.1 degrees in group O (p = 0.570). The inlier rate was not significantly different between group C and group O (HKA: 64.6 vs. 71.9%, p = 0.521; MPTA: 67.7 vs. 78.1%, p = 0.372; PTS: 82.2 vs. 77.8%, p = 0.667). The accuracy of tibial bone cutting for the obese group was comparable to that of the control group. An accelerometer-based portable navigation system can be useful when attempting to achieve the target tibial alignment in obese patients. Level of Evidence Level IV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Mitsui Memorial Hospital, Chiyoda-ku, Tokyo, Japan.
- Department of Orthopaedic Surgery, Center Hospital of the National Center for Global Health and Medicine, Shinjuku-ku, Tokyo, Japan.
ORCID-Profile: Kazumi Goto
Zitieren
APA
Goto, K., Hirota, J., Miyamoto, Y., & Katsuragawa, Y. (2024). The Accuracy of a Portable Accelerometer-Based Navigation System for Tibial Alignment Can be Reliable during Total Knee Arthroplasty for Obese Patients. The Journal of Knee Surgery, 37(04), 303-309. https://doi.org/10.1055/a-2094-8822
Vancouver
Goto K, Hirota J, Miyamoto Y, Katsuragawa Y. The Accuracy of a Portable Accelerometer-Based Navigation System for Tibial Alignment Can be Reliable during Total Knee Arthroplasty for Obese Patients. The Journal of Knee Surgery. 2024;37(04):303-309. doi:10.1055/a-2094-8822
BibTeX
@article{Goto2024,
author = {Goto, Kazumi and Hirota, Jinso and Miyamoto, Yoshinari and Katsuragawa, Yozo},
title = {The Accuracy of a Portable Accelerometer-Based Navigation System for Tibial Alignment Can be Reliable during Total Knee Arthroplasty for Obese Patients},
journal = {The Journal of Knee Surgery},
year = {2024},
volume = {37},
number = {04},
pages = {303--309},
doi = {10.1055/a-2094-8822}
}