Are Low Weight or Cardiopathy Contraindications for Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula?
European Journal of Pediatric Surgery · 01.08.2024 · 34 (04) · 301-305
DOI: 10.1055/a-2072-9754 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Pediatric Surgery, erschienen am 01.08.2024. Verfasst von Carlos Cadaval und 10 weiteren Autor:innen. Beteiligte Einrichtung: Neonatal Surgery Unit, Department of Pediatric Surgery and Urology, Universitat Autónoma de Barcelona, Barcelona, Spain. Hauptthemen laut MEDLINE: Esophageal Atresia, Tracheoesophageal Fistula, Thoracoscopy, Infant, Low Birth Weight. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Background
Thoracoscopic repair of esophageal atresia (EA) with tracheoesophageal fistula (TEF) is becoming an increasingly widespread technique; there is still controversy about its indication in certain patients. Our objective is to analyze if potential risk factors such as major congenital heart disease (CHD) or low birth weight (LBW) are a limitation to this approach.
Methods
Retrospective study (2017–2021) of patients with EA and distal TEF who underwent thoracoscopic repair were included. Patients with LBW less than 2,000 g or major CHD were compared with the rest.
Results
Twenty-five patients underwent thoracoscopic surgery. Nine patients (36%) had major CHD. Five of them (20%) were LBW less than 2,000 g, and only 8% (2/25) presented both risk factors. There were no differences in terms of operative time, conversion rate, tolerance evaluated with gasometric parameters (pO2, pCO2, pH) or complications (anastomotic leak and stricture, both early or during follow-up) in patients with major CHD and LBW (1,473 ± 319 vs. 2,664 ± 402 g). One conversion to thoracotomy was performed in a neonate weighing 1,050 g due to anesthetic intolerance. There was no recurrence of TEF. One patient died at the age of 9 months, due to major uncorrectable heart disease.
Conclusion
Thoracoscopic repair of EA/TEF is feasible technique in patients with CHD or LBW, with similar results to other patients. The complexity of this technique warrants individualizing the indication in each case. Level of Evidence IV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Neonatal Surgery Unit, Department of Pediatric Surgery and Urology, Universitat Autónoma de Barcelona, Barcelona, Spain.
- Department of Pediatric Surgery and Urology, Universitat Autónoma de Barcelona, Barcelona, Spain.
- Division of Pediatric Anestethesiology, Universitat Autónoma de Barcelona, Barcelona, Spain.
- Division of Neonatology, Universitat Autónoma de Barcelona, Barcelona, Spain.
ORCID-Profile: José Andrés Molino
Zitieren
APA
Cadaval, C., Molino, J. A., Guillén, G., López Fernández, S., Hierro, C. L., Martos Rodríguez, M., Khan, H. A., Vilardell, E., Andreu, E., Ruiz, C. W., & López, M. (2024). Are Low Weight or Cardiopathy Contraindications for Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula?. European Journal of Pediatric Surgery, 34(04), 301-305. https://doi.org/10.1055/a-2072-9754
Vancouver
Cadaval C, Molino JA, Guillén G, López Fernández S, Hierro CL, Martos Rodríguez M, et al. Are Low Weight or Cardiopathy Contraindications for Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula?. European Journal of Pediatric Surgery. 2024;34(04):301-305. doi:10.1055/a-2072-9754
BibTeX
@article{Cadaval2024,
author = {Cadaval, Carlos and Molino, José Andrés and Guillén, Gabriela and López Fernández, Sergio and Hierro, Carmen López and Martos Rodríguez, Marta and Khan, Haider Ali and Vilardell, Elena and Andreu, Eva and Ruiz, César W and López, Manuel},
title = {Are Low Weight or Cardiopathy Contraindications for Thoracoscopic Repair of Esophageal Atresia with Tracheoesophageal Fistula?},
journal = {European Journal of Pediatric Surgery},
year = {2024},
volume = {34},
number = {04},
pages = {301--305},
doi = {10.1055/a-2072-9754}
}
EUVIMED