Use of a novel biliary stent to prevent distal stent migration in benign anastomotic stricture
Endoscopy · 01.12.2023 · 55 (S 01 S 01) · E654-E655
DOI: 10.1055/a-2067-4442 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Hirokazu Saito und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Kumamoto City Hospital, Kumamoto, Japan. Hauptthemen laut MEDLINE: Biliary Tract, Cholestasis. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Endoscopic treatment using balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography (ERCP) is useful for hepaticojejunostomy anastomotic strictures. Although biliary stent placement is conducted to avoid stricture recurrence or realize stricture resolution after balloon dilation [ 1 ] [ 2 ], distal stent migration is a common problem [ 3 ] [ 4 ]. An 11-year-old-boy, who had undergone hepaticojejunostomy for pancreaticobiliary maljunction 1 year earlier, underwent single-balloon endoscope-assisted ERCP to resolve a benign anastomotic stricture ([ Fig. 1 a ]). After balloon dilation, a 7-Fr straight-type plastic stent was placed into the intrahepatic bile duct to prevent stricture recurrence ([ Fig. 1 b ]). However, distal stent migration occurred at 4 weeks after the procedure. Fig. 1 Endoscopic images. a After hepaticojejunostomy for pancreaticobiliary maljunction, a benign anastomotic stricture was noticed. b A 7-Fr straight-type plastic stent was placed into the intrahepatic bile duct after balloon dilation. We used a novel 7-Fr Tanenbaum-type biliary stent integrated with a nasobiliary drainage catheter (UMIZAS NB STENT; Olympus Medical System, Tokyo, Japan) to prevent distal stent migration ([ Fig. 2 a ]). As the attached pusher catheter was too short to place the stent using a short-type enteroscope (SIF-H290S; Olympus Medical System), the outer sheath of a snare designed for the colon (Snare Master; Olympus Medical System) was used as the pusher catheter. First, we cut the outer sheath of the snare at the proximal side ([ Fig. 2 b ], [ Video 1 ]) and covered the nasobiliary drainage catheter with the outer sheath of the snare after withdrawing the associated pusher catheter. The inner nasobiliary catheter protruded approximately 15 mm from the tip of the stent, and the outer sheath and nasobiliary catheter were fixed with tape. The nasobiliary catheter and outer sheath were removed after the 7-Fr biliary stent was placed into the intrahepatic duct ([ Fig. 2 c ]). After 3 months, there was no evidence of distal stent migration. Fig. 2 The novel biliary stent. a Novel 7-Fr Tanenbaum-type stent integrated with a nasobiliary drainage catheter. However, when used with a short-type enteroscope, which has a length of 167 cm between the forceps channel and the tip of the scope, the effective length of the attached pusher catheter was only 155 cm, making it impossible to place the stent. b The outer sheath of a snare designed for the colon, which has an effective length of 220 cm, was cut at the proximal side to use as the pusher catheter. This outer sheath was 7.3 Fr and just fitted over the 7-Fr biliary stent. c Using a short-type enteroscope, the 7-Fr biliary stent was inserted into the intrahepatic duct. Video 1 Use of a novel outside biliary stent with the outer sheath of a snare designed for the colon to avoid distal stent migration for a benign hepaticojejunostomy anastomotic stricture. Download Video To reduce distal stent migration, a unique 7-Fr biliary stent integrated with a nasobiliary drainage catheter using the outer sheath of a snare designed for the colon may be helpful in surgically altered anatomy. Endoscopy_UCTN_Code_TTT_1AR_2AZ Endoscopy E-Videos https://eref.thieme.de/e-videos E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/ ). This section has its own submission website at https://mc.manuscriptcentral.com/e-videos Publication History Article published online: 21 April 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Gastroenterology, Kumamoto City Hospital, Kumamoto, Japan.
Zitieren
APA
Saito, H., Kadowaki, Y., Fujimoto, A., Ohmoto, K., & Tada, S. (2023). Use of a novel biliary stent to prevent distal stent migration in benign anastomotic stricture. Endoscopy, 55(S 01 S 01), E654-E655. https://doi.org/10.1055/a-2067-4442
Vancouver
Saito H, Kadowaki Y, Fujimoto A, Ohmoto K, Tada S. Use of a novel biliary stent to prevent distal stent migration in benign anastomotic stricture. Endoscopy. 2023;55(S 01 S 01):E654-E655. doi:10.1055/a-2067-4442
BibTeX
@article{Saito2023,
author = {Saito, Hirokazu and Kadowaki, Yoshitaka and Fujimoto, Atsushi and Ohmoto, Kana and Tada, Shuji},
title = {Use of a novel biliary stent to prevent distal stent migration in benign anastomotic stricture},
journal = {Endoscopy},
year = {2023},
volume = {55},
number = {S 01 S 01},
pages = {E654--E655},
doi = {10.1055/a-2067-4442}
}
EUVIMED