EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Role of Helicopter Transfer and Cloud-Type Imaging for Acute Type A Aortic Dissection

Natsuya Ishikawa, Masahiko Narita iD, Tomonori Shirasaka iD, Ryouhei Ushioda, Masahiro Tsutsui, Nobuyoshi Azuma, Hiroyuki Kamiya

The Thoracic and Cardiovascular Surgeon · 01.03.2024 · 72 (02) · 105-117

DOI: 10.1055/a-2031-3763 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Thoracic and Cardiovascular Surgeon, erschienen am 01.03.2024. Verfasst von Natsuya Ishikawa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan. Hauptthemen laut MEDLINE: Aortic Dissection. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study explored if long-distance transfer was safe for patients suffering from acute aortic dissection type A (AADA) and also analyzed the effectiveness of helicopter transfer and cloud-type imaging transfer systems for such patients in northern Hokkaido, Japan. Methods and Results The study included 112 consecutive patients who underwent emergency surgical treatment for AADA from April 2014 to September 2020. The patients were divided into two groups according to the location of referral source hospitals: the Asahikawa city group (group A, n = 49) and the out-of-the-city group (group O, n = 63). Use of helicopter transfer (n = 13) and cloud-type telemedicine (n = 20) in group O were reviewed as subanalyses. Transfer distance differed between groups (4.2 ± 3.5 km in group A vs 107.3 ± 69.2 km in group O; p = 0.0001), but 30-day mortality (10.2% in group A vs 7.9% in group O; p = 0.676) and hospital mortality (12.2% in group A vs 9.5% in group O; p = 0.687) did not differ. Operative outcomes did not differ with or without helicopter and cloud-type telemedicine, but diagnosis-to-operation time was shorter with helicopter (240.0 ± 70.8 vs 320.0 ± 78.5 minutes; p = 0.031) and telemedicine (242.0 ± 75.2 vs 319.0 ± 83.8 minutes; p = 0.007).

Conclusion

We found that long-distance transfer did not impair surgical outcomes in AADA patients, and both helicopter transfer and cloud-type telemedicine system could contribute to the reduction of diagnosis-to-operation time in the large Hokkaido area. Further studies are mandatory to investigate if both the systems will improve clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic DissectionHumansTreatment OutcomeAircraftJapanRetrospective Studies

Autor:innen und Institutionen

  • Department of Cardiac Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan.
  • Department of Vascular Surgery, Asahikawa Medical University, Asahikawa, Hokkaido, Japan.

ORCID-Profile: Masahiko Narita, Tomonori Shirasaka

Zitieren

APA

Ishikawa, N., Narita, M., Shirasaka, T., Ushioda, R., Tsutsui, M., Azuma, N., & Kamiya, H. (2024). Role of Helicopter Transfer and Cloud-Type Imaging for Acute Type A Aortic Dissection. The Thoracic and Cardiovascular Surgeon, 72(02), 105-117. https://doi.org/10.1055/a-2031-3763

Vancouver

Ishikawa N, Narita M, Shirasaka T, Ushioda R, Tsutsui M, Azuma N, et al. Role of Helicopter Transfer and Cloud-Type Imaging for Acute Type A Aortic Dissection. The Thoracic and Cardiovascular Surgeon. 2024;72(02):105-117. doi:10.1055/a-2031-3763

BibTeX
@article{Ishikawa2024,
  author = {Ishikawa, Natsuya and Narita, Masahiko and Shirasaka, Tomonori and Ushioda, Ryouhei and Tsutsui, Masahiro and Azuma, Nobuyoshi and Kamiya, Hiroyuki},
  title = {Role of Helicopter Transfer and Cloud-Type Imaging for Acute Type A Aortic Dissection},
  journal = {The Thoracic and Cardiovascular Surgeon},
  year = {2024},
  volume = {72},
  number = {02},
  pages = {105--117},
  doi = {10.1055/a-2031-3763}
}
Kostenlos starten →