Bilateral Implantation of Multifocal Intraocular Lenses: 10-Year Follow-Up
Klinische Monatsblätter für Augenheilkunde · 01.04.2023 · 240 (04) · 426-434
DOI: 10.1055/a-2031-2556 ↗Kurz gefasst
Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 01.04.2023. Verfasst von Rosa Giglio und 9 weiteren Autor:innen. Beteiligte Einrichtung: Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy. Hauptthemen laut MEDLINE: Multifocal Intraocular Lenses, Lenses, Intraocular, Phacoemulsification. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Purpose
To evaluate and compare the long-term results after bilateral implantation of different multifocal intraocular lenses (MIOLs).
Methods
This retrospective comparative study included 42 patients who underwent cataract surgery with bilateral MIOL implantation. Patients were divided into 5 groups: Group 1 received a refractive ReZoom NGX1 IOL (AMO), Group 2 a diffractive Acrysof ReSTOR SA60D3 IOL (Alcon), and Group 3 a diffractive Tecnis ZM900 IOL (AMO). Group 4 and Group 5 were implanted using the mix and match approach with refractive ReZoom-diffractive ReSTOR IOL and refractive ReZoom-diffractive Tecnis ZM900 IOL, respectively. Primary outcome measures were distance, near, and intermediate distance visual acuity measured 6 months (T0) and 10 years (T1) after surgery. Secondary outcomes were defocus curves, contrast sensitivity, patientsʼ satisfaction, and spectacle independence.
Results
All patients achieved best-corrected distance visual acuity (BCDVA) greater than 0.11 logMAR and uncorrected distance visual acuity (UCDVA) greater than 0.14 logMAR at both time points. A decrease in contrast sensitivity was evident, particularly at high spatial frequencies; at T1, Group 4 reported statistically higher values than Group 2 at 12 cycles/degree and 18 cycles/degree and statistically higher values than Group 3 at 18 cycles/degree. Great overall satisfaction was reported even in the presence of dysphotopsia. Tecnis ZM900 IOL showed the lowest incidence of posterior capsular opacification.
Conclusion
MIOLs could provide adequate functional vision and patient satisfaction, despite the incidence of side effects, in carefully selected patients desiring spectacle independence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy.
- Eye Clinic, Department of Public Health, University of Naples Federico II, Napoli, Italy.
- Chair and Department of General and Paediatric Ophthalmology, Medical University of Lublin, Lublin, Poland.
- Eye Clinic, University Hospital Zürich, Zurich, Switzerland.
Zitieren
APA
Giglio, R., De Giacinto, C., Inferrera, L., Fanni, D., Milan, S., Cuna, A., Toro, M. D., Zweifel, S., Ravalico, G., & Tognetto, D. (2023). Bilateral Implantation of Multifocal Intraocular Lenses: 10-Year Follow-Up. Klinische Monatsblätter für Augenheilkunde, 240(04), 426-434. https://doi.org/10.1055/a-2031-2556
Vancouver
Giglio R, De Giacinto C, Inferrera L, Fanni D, Milan S, Cuna A, et al. Bilateral Implantation of Multifocal Intraocular Lenses: 10-Year Follow-Up. Klinische Monatsblätter für Augenheilkunde. 2023;240(04):426-434. doi:10.1055/a-2031-2556
BibTeX
@article{Giglio2023,
author = {Giglio, Rosa and De Giacinto, Chiara and Inferrera, Leandro and Fanni, Daniela and Milan, Serena and Cuna, Alessandra and Toro, Mario Damiano and Zweifel, Sandrine and Ravalico, Giuseppe and Tognetto, Daniele},
title = {Bilateral Implantation of Multifocal Intraocular Lenses: 10-Year Follow-Up},
journal = {Klinische Monatsblätter für Augenheilkunde},
year = {2023},
volume = {240},
number = {04},
pages = {426--434},
doi = {10.1055/a-2031-2556}
}