Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Li Zhong und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. Hauptthemen laut MEDLINE: Self Expandable Metallic Stents, Intestinal Obstruction. Die Arbeit nennt 4 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For malignant gastrointestinal obstruction in inoperable patients, the self-expandable metal stent (SEMS) is a useful nonsurgical palliative treatment to improve patients’ quality of life [ 1 ] [ 2 ] [ 3 ] [ 4 ]. The common method of intestinal stent placement is to navigate the guidewire through the narrow segment, which often takes a long time, and sometimes leads to stent placement failure because the guidewire cannot pass through the narrow segment. Here, we describe the successful endoscopic placement of an SEMS using a guidewire after a digital cholangioscope was used to pass through the narrow small intestine. A 46-year-old man was diagnosed with unresectable primary carcinoma of the horizontal segment of the duodenum with severe intestinal obstruction. After failure of conventional stent placement, we attempted to use a digital cholangioscope to place the guidewire through the narrow segment and guide the SEMS ([ Video 1 ]). First, a digital cholangioscope (eyeMax; Micro-Tech Nanjing, Co., Ltd, Nanjing, China) was inserted through the stenosis and a 0.35-mm guidewire was introduced into the distal small intestine under direct visualization ([ Fig. 1 ]). After retrieval of the digital cholangioscope, the uncovered SEMS was advanced over the wire through the stenosis and gradually deployed under continuous X-ray monitoring ([ Fig. 2 ]). Stent patency was evaluated with iodine contrast agent immediately after placement ([ Fig. 3 ]). Video 1 Endoscopic placement of a self-expandable metal stent was performed using a digital cholangioscope-guided approach. Download Video Fig. 1 Guidewire placement into the distal small intestine under direct visualization using a digital cholangioscope. a A digital cholangioscope was inserted through the stenosis. b A 0.35-mm guidewire was placed into the distal small intestine under direct visualization. Fig. 2 Endoscopic view of the stent placed for the treatment of intestinal obstruction due to primary carcinoma of the horizontal segment of the duodenum. Fig. 3 Stent patency was evaluated immediately after placement using X-ray with iodine contrast agent. The patient was allowed to drink clear liquid on the second day after the operation, and advanced to a low-residue diet on the third day. For patients with intestinal obstruction, this technique is a fast and effective method for stent placement. Endoscopy_UCTN_Code_TTT_1AP_2AD Endoscopy E-Videos https://eref.thieme.de/e-videos Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available. This section has its own submission website at https://mc.manuscriptcentral.com/e-videos Publication History Article published online: 03 February 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Self Expandable Metallic StentsIntestinal ObstructionHumansCatheterizationIntestine, SmallStentsRetrospective StudiesTreatment OutcomePalliative Care

Autor:innen und Institutionen

  • Department of Gastroenterology, The Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.

ORCID-Profile: Chao Deng

Zitieren

APA

Zhong, L., Qiu, C., Yi, H., He, S., Wu, S., Deng, C., & Ning, B. (2023). Endoscopic placement of a self-expandable metal stent for malignant small-intestine obstruction using a digital cholangioscope-guided approach. Endoscopy, 55(S 01 S 01), E408-E409. https://doi.org/10.1055/a-2008-0376

Vancouver

Zhong L, Qiu C, Yi H, He S, Wu S, Deng C, et al. Endoscopic placement of a self-expandable metal stent for malignant small-intestine obstruction using a digital cholangioscope-guided approach. Endoscopy. 2023;55(S 01 S 01):E408-E409. doi:10.1055/a-2008-0376

BibTeX
@article{Zhong2023,
  author = {Zhong, Li and Qiu, Chan and Yi, Hang and He, Song and Wu, Suhua and Deng, Chao and Ning, Bo},
  title = {Endoscopic placement of a self-expandable metal stent for malignant small-intestine obstruction using a digital cholangioscope-guided approach},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 01 S 01},
  pages = {E408--E409},
  doi = {10.1055/a-2008-0376}
}
Kostenlos starten →