Vergleichsstudie in der Zeitschrift Experimental and Clinical Endocrinology & Diabetes, erschienen am 01.03.2023. Verfasst von Sebastian Hörber und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Germany. Hauptthemen laut MEDLINE: Clinical Relevance. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
C-peptide is an increasingly used and established marker for beta cell function by assessing endogenous insulin secretion. Accurate and comparable C-peptide measurements are needed in clinical practice and research studies. For example, to calculate HOMA-indices, the C-peptide/glucose ratio, and the classification of recently published novel subgroups of diabetes and prediabetes have used C-peptide measurements. Although the process for standardization of C-peptide measurements is advanced, its full implementation is still missing; therefore, the current status of the comparability of C-peptide measurements using different immunoassays is unclear. Here we compared five widely used C-peptide immunoassays on different analyzers (Abbott ALINITY i, DiaSorin Liaison XL, Roche Cobas e411, Siemens Healthineers ADVIA Centaur XPT, and Immulite 2000 XPi) using serum samples covering the clinically relevant C-peptide concentration range. Although all investigated immunoassays are traceable to the international reference reagent for C-peptide (NIBSC code: 84/510), results of C-peptide measurements showed significant differences between analyzers in the entire concentration range, especially with increasing C-peptide concentrations. The mean bias was largest (36.6%) between results of the immunoassays by Roche and Siemens Healthineers (ADVIA Centaur XPT), and both assays revealed large discrepancies compared to immunoassays by Abbott, DiaSorin, and Siemens Healthineers (Immulite 2000 XPi). In contrast, the three latter assays showed similar C-peptide results (mean bias: 2.3% to 4.2%). Consequently, C-peptide discrepancies might affect clinical diagnosis and the interpretation of study results. Therefore, there is an urgent need to implement and finalize the standardization process of C-peptide measurements to improve patient care and the comparability of research studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute for Clinical Chemistry and Pathobiochemistry, Department for Diagnostic Laboratory Medicine, University Hospital Tübingen, Germany.
- Institute for Diabetes Research and Metabolic Diseases of the Helmholtz Center Munich at the University of Tübingen, Germany.
- German Center for Diabetes Research (DZD), München-Neuherberg, Germany.
- Institute of Laboratory Medicine, Vinzenz von Paul Kliniken gGmbH, Stuttgart, Germany.
- Department of Internal Medicine IV, Division of Endocrinology, Diabetology and Nephrology, University of Tübingen, Germany.
Zitieren
APA
Hörber, S., Orth, M., Fritsche, A., & Peter, A. (2023). Comparability of C-Peptide Measurements – Current Status and Clinical Relevance. Experimental and Clinical Endocrinology & Diabetes, 131(03), 173-178. https://doi.org/10.1055/a-1998-6889
Vancouver
Hörber S, Orth M, Fritsche A, Peter A. Comparability of C-Peptide Measurements – Current Status and Clinical Relevance. Experimental and Clinical Endocrinology & Diabetes. 2023;131(03):173-178. doi:10.1055/a-1998-6889
BibTeX
@article{Hrber2023,
author = {Hörber, Sebastian and Orth, Matthias and Fritsche, Andreas and Peter, Andreas},
title = {Comparability of C-Peptide Measurements – Current Status and Clinical Relevance},
journal = {Experimental and Clinical Endocrinology & Diabetes},
year = {2023},
volume = {131},
number = {03},
pages = {173--178},
doi = {10.1055/a-1998-6889}
}
EUVIMED