Virtual scale endoscope-assisted wide-field resection of large sessile serrated lesions
Endoscopy · 01.12.2023 · 55 (S 01 S 01) · E314-E315
DOI: 10.1055/a-1981-2392 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Roupen Djinbachian und 1 weiteren Autor:innen. Beteiligte Einrichtung: Division of Gastroenterology, Montreal University Hospital Center (CHUM), Montreal, Canada. Hauptthemen laut MEDLINE: Colonic Polyps, Colorectal Neoplasms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Large sessile serrated lesions (SSLs) are associated with a very high risk of incomplete resection. The CARE study found almost 50 % incomplete resections among 10 to 20-mm SSLs [ 1 ]. Wide-field cold snare resection with submucosal injection (cap-assisted endoscopic mucosal resection, C-EMR) has been proposed as an effective method to prevent incomplete resection since distinguishing SSL margins during resection is difficult [ 2 ] [ 3 ] [ 4 ]. In contrast to a hot snare, a more extended resection field is recommended for a cold snare [ 5 ]. However, quantification of the resection field extent in comparison to polyp size has been challenging in the past. The novel virtual scale endoscope (VSE; SCALE EYE, Fujifilm, Tokyo, Japan) can be used as dedicated technology to measure polyp size before resection and to ensure adequate post-resection defect size. The VSE allows polyp size measurement during live colonoscopies by emitting a laser beam onto the mucosa to measure distance. This permits superimposition of a linear/circular ruler that changes in size depending on distance of the endoscope to the laser point ([ Fig. 1 ]). Fig. 1 Virtual scale endoscope with laser point on polyp from which a scale is projected on the endoscopy screen. We present VSE-assisted C-EMR for two large SSLs ([ Video 1 ]). The polyps were assessed with the VSE before and after submucosal injection and resection to ensure adequate wide-field resection. SSLs were initially measured using the VSE and assessed using computer-aided diagnosis (CADx) to determine their size (> 10 mm) and ensure that C-EMR was the adequate approach. Then the extent of wide-field resection was planned and controlled using the VSE. For resection, submucosal injection was used to allow better exposure of the entire polyp and obtain a pre-resection measurement using the VSE ([ Fig. 2 ]). The polyps were then resected, and an artificial-intelligence system (CADx) was used to detect polyp remnants at the margins during C-EMR ([ Fig. 3 ]). The resection extent was adjusted based on CADx and VSE information to ensure adequate and complete wide-field resection. The final resection defect size was measured to ensure that it was significantly larger than the pre-resection polyp size after submucosal injection ([ Fig. 4 ]). Video 1 Virtual scale endoscope-assisted resection of two large sessile serrated polyps with pre-resection measurement of the polyps and post-resection measurement of the resulting defect for wide field margins. Quality: mobile 360 480 720 Download Fig. 2 Post-submucosal injection size measurement with virtual scale endoscope for polyp 1. Fig. 3 Computer-aided diagnosis of polyp remnant. Fig. 4 Resection defect size measurement for polyp 1. Endoscopy_UCTN_Code_TTT_1AQ_2AD Endoscopy E-Videos https://eref.thieme.de/e-videos Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available. This section has its own submission website at https://mc.manuscriptcentral.com/e-videos Publication History Article published online: 13 December 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Gastroenterology, Montreal University Hospital Center (CHUM), Montreal, Canada.
- Montreal University Hospital Research Center (CRCHUM), Montreal, Canada.
ORCID-Profile: Roupen Djinbachian, Daniel von Renteln
Zitieren
APA
Djinbachian, R., & von Renteln, D. (2023). Virtual scale endoscope-assisted wide-field resection of large sessile serrated lesions. Endoscopy, 55(S 01 S 01), E314-E315. https://doi.org/10.1055/a-1981-2392
Vancouver
Djinbachian R, von Renteln D. Virtual scale endoscope-assisted wide-field resection of large sessile serrated lesions. Endoscopy. 2023;55(S 01 S 01):E314-E315. doi:10.1055/a-1981-2392
BibTeX
@article{Djinbachian2023,
author = {Djinbachian, Roupen and von Renteln, Daniel},
title = {Virtual scale endoscope-assisted wide-field resection of large sessile serrated lesions},
journal = {Endoscopy},
year = {2023},
volume = {55},
number = {S 01 S 01},
pages = {E314--E315},
doi = {10.1055/a-1981-2392}
}
EUVIMED