EUVIMEDEUVIMED entdecken
Crossref

Effects on Wavefront Aberration after Short-term Wear of Senofilcon A Photochromic Contact Lens

Ömer Faruk Recep, Dilara Ozkoyuncu Kocabas iD, Hasan Kiziltoprak, Kemal Ozulken

Klinische Monatsblätter für Augenheilkunde · 01.08.2024 · 241 (08) · 982-989

DOI: 10.1055/a-1973-8904 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 01.08.2024. Verfasst von Ömer Faruk Recep und 3 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology, 19 Mayis Hospital, Ankara, Turkey. Hauptthemen laut MEDLINE: Corneal Wavefront Aberration. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To assess the variability in wavefront aberrations with short-term wear of photochromic senofilcon A contact lenses in both its activated and inactive states. Methods and Material In this cross-sectional study, 20 participants who had previously used soft contact lenses were enrolled. Corneal aberrometry measurements were performed on each subject, without contact lenses, using Sirius Scheimpflug-Placido topography. The photochromic lenses were illuminated using a blue-violet light (λ max = 420 nm) so as to provoke an activated state, and measurements were taken with the lenses inserted, in both states. The root mean square (RMS) of the aberrations was calculated, and the higher- and lower-order aberrations, astigmatism, coma, spherical aberration, and trefoil measurements were evaluated using a 5.0-mm pupil diameter.

Results

The average contact lens sphere power was − 2.33 ± 1.07 D. The mean refractive errors with contact lens wear were 0.07 ± 0.18 D for the sphere and − 0.26 ± 0.15 D for the cylinder. The mean RMS values for all the corneal aberrations showed no statistically significant differences with and without contact lenses (p > 0.05). In a bivariate correlation analysis, there was a positive correlation between contact lens sphere power and coma (vertical and horizontal) in the activated state (r = 0.455, p = 0.44 and r = 0.495, p = 0.27, respectively).

Conclusion

The photochromic contact lenses did not influence ocular aberration during short-term wear, even when the photochromatic additive was activated. This property may help to provide more comfortable vision with lens wear. This finding needs to be verified by further studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Corneal Wavefront AberrationHumansFemaleMaleAdultYoung AdultContact Lenses, HydrophilicCorneal TopographyRefractive ErrorsTreatment OutcomeCross-Sectional StudiesEquipment Failure AnalysisSiliconesHydrogels

Substanzen

senofilcon ASiliconesHydrogels

Autor:innen und Institutionen

  • Ophthalmology, 19 Mayis Hospital, Ankara, Turkey.
  • Ophthalmology, TOBB Economics and Technology University Faculty of Medicine, Ankara, Turkey.
  • Ophthalmology, Adıyaman University Training and Research Hospital, Adıyaman, Turkey.

ORCID-Profile: Dilara Ozkoyuncu Kocabas

Zitieren

APA

Recep, Ö. F., Kocabas, D. O., Kiziltoprak, H., & Ozulken, K. (2024). Effects on Wavefront Aberration after Short-term Wear of Senofilcon A Photochromic Contact Lens. Klinische Monatsblätter für Augenheilkunde, 241(08), 982-989. https://doi.org/10.1055/a-1973-8904

Vancouver

Recep ÖF, Kocabas DO, Kiziltoprak H, Ozulken K. Effects on Wavefront Aberration after Short-term Wear of Senofilcon A Photochromic Contact Lens. Klinische Monatsblätter für Augenheilkunde. 2024;241(08):982-989. doi:10.1055/a-1973-8904

BibTeX
@article{Recep2024,
  author = {Recep, Ömer Faruk and Kocabas, Dilara Ozkoyuncu and Kiziltoprak, Hasan and Ozulken, Kemal},
  title = {Effects on Wavefront Aberration after Short-term Wear of Senofilcon A Photochromic Contact Lens},
  journal = {Klinische Monatsblätter für Augenheilkunde},
  year = {2024},
  volume = {241},
  number = {08},
  pages = {982--989},
  doi = {10.1055/a-1973-8904}
}
Kostenlos starten →