A novel technique of intraductal ultrasonography using a newly designed endoscopic sheath and Y-connector during endoscopic retrograde cholangiography

Koichiro Mandai iD, Takato Inoue

Endoscopy · 01.12.2023 · 55 (S 01 S 01) · E159-E160

DOI: 10.1055/a-1953-7219 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Koichiro Mandai und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Kyoto Second Red Cross Hospital, Kyoto, Japan. Hauptthemen laut MEDLINE: Cholangiography, Catheterization. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 1 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intraductal ultrasonography (IDUS) is a useful diagnostic modality for the detection of biliary stones [ 1 ]. However, conventional IDUS cannot provide accurate cross-sectional imaging of the bile duct in patients with pneumobilia. To overcome this limitation, we describe a novel IDUS technique using a newly designed endoscopic sheath and Y-connector to confirm complete biliary stone removal. A 78-year-old woman was referred to our hospital due to acute cholangitis caused by biliary stones. Endoscopic sphincterotomy and transpapillary biliary drainage were performed. Four days later, biliary stone removal was performed using a basket catheter, and IDUS using a newly designed endoscopic sheath and Y-connector was carried out to confirm complete extraction. First, an endoscopic sheath (outer and inner diameters 2.4 mm and 2.06 mm, respectively; Endosheather; Piolax Medical Devices, Kanagawa, Japan) was inserted over the guidewire. The inner catheter and guidewire were removed, and the outer sheath was left in place. After a Y-connector with a 10-Fr internal lumen (Okay II; Goodman, Aichi, Japan) was attached to the proximal end of the outer sheath, a 1.8-mm-diameter ultra-slim radial ultrasonic probe (UM-S20-17S; Olympus Medical Systems, Tokyo, Japan) was inserted through the Y-connector and outer sheath ([ Fig. 1 ]). Fluoroscopy and IDUS confirmed that the probe tip emerged slightly from the tip of the outer sheath, and then the valve of the Y-connector was closed to fix the probe. IDUS was performed while the outer sheath was withdrawn along with the probe. During IDUS, air bubbles were aspirated and saline-diluted contrast medium was injected through the sideport as needed ([ Fig. 2 ]). The inside of the bile duct could be clearly observed and complete stone removal was confirmed ([ Video 1 ]). Fig. 1 a The tip of the ultra-slim ultrasonic probe emerges from the tip of the outer sheath (blue arrow) of the Endosheather. b The Y-connector with a 10-Fr internal lumen is attached to the proximal end of the outer sheath (red arrow). The ultra-slim ultrasonic probe (yellow arrow) is inserted through the Y-connector and outer sheath. Fig. 2 a The inside of the bile duct cannot be observed due to air bubbles. b After air bubbles are aspirated and saline-diluted contrast medium diluted is injected through the Endosheather, the inside of the bile duct can be clearly observed. Video 1 Endoscopic sheath-assisted intraductal ultrasonography to confirm complete removal of biliary stones. Quality: mobile 360 480 720 Download This case suggests that this novel IDUS technique using a newly designed endoscopic sheath and Y-connector is promising for bile duct evaluation in patients with pneumobilia. Endoscopy_UCTN_Code_TTT_1AS_2AD Endoscopy E-Videos https://eref.thieme.de/e-videos Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available. This section has its own submission website at https://mc.manuscriptcentral.com/e-videos Publication History Article published online: 28 October 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany Comment to this article: Endoscopy E-Videos – recently published Endoscopy 2023; 55(04): 390-390 DOI: 10.1055/a-2009-2004

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CholangiographyCatheterizationHumansUltrasonographyCholangiopancreatography, Endoscopic Retrograde

Autor:innen und Institutionen

  • Department of Gastroenterology, Kyoto Second Red Cross Hospital, Kyoto, Japan.

ORCID-Profile: Koichiro Mandai

Zitieren

APA

Mandai, K., & Inoue, T. (2023). A novel technique of intraductal ultrasonography using a newly designed endoscopic sheath and Y-connector during endoscopic retrograde cholangiography. Endoscopy, 55(S 01 S 01), E159-E160. https://doi.org/10.1055/a-1953-7219

Vancouver

Mandai K, Inoue T. A novel technique of intraductal ultrasonography using a newly designed endoscopic sheath and Y-connector during endoscopic retrograde cholangiography. Endoscopy. 2023;55(S 01 S 01):E159-E160. doi:10.1055/a-1953-7219

BibTeX
@article{Mandai2023,
  author = {Mandai, Koichiro and Inoue, Takato},
  title = {A novel technique of intraductal ultrasonography using a newly designed endoscopic sheath and Y-connector during endoscopic retrograde cholangiography},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 01 S 01},
  pages = {E159--E160},
  doi = {10.1055/a-1953-7219}
}
Kostenlos starten →