Providing Positive End-Expiratory Pressure during Neonatal Resuscitation: A Meta-analysis
Positiver endexpiratorischer Druck (PEEP) während der neonatalen Reanimation: Metaanalyse
American Journal of Perinatology · 01.04.2024 · 41 (06) · 690-699
DOI: 10.1055/a-1933-7235 ↗Auf einen Blick
10 Studien mit 4.268 Neugeborenen zeigen: PEEP war mit geringerer Mortalität bis zur Entlassung verbunden. Der Effekt zeigte sich bei Frühgeborenen, nicht bei Termingeborenen.
Fragestellung
Welche Effekte hat die Gabe von PEEP während der neonatalen Reanimation bei Geburt?
Methode
Systematische Übersicht und Metaanalyse randomisierter und Kohortenstudien; Suche in Medline, Web of Science, Scopus, Cochrane Central Register of Controlled Trials und Clinicaltrials.gov bis 15. Dezember 2020; GRADE.
Ergebnisse
10 Studien, 4.268 Neugeborene; 5 RCTs, 1 quasi-randomisierte Studie und 4 Kohortenstudien. Mortalität bis Entlassung: OR 0,60 (95 %-KI 0,49–0,74), moderate Evidenz. Frühgeborene: OR 0,57 (95 %-KI 0,46–0,69); Termingeborene: OR 1,03 (95 %-KI 0,52–2,02).
Einschränkungen
Evidenz für Termingeborene begrenzt und nicht schlüssig; weitere Forschung zu optimalem Gerät und Langzeiteffekten erforderlich.
Schlussfolgerung der Autor:innen
Die Autor:innen folgern, dass PEEP bei der neonatalen Reanimation mit geringerer Mortalität bei Frühgeborenen verbunden ist.
Kernaussagen
- Mortalität bis Entlassung mit PEEP geringer
- Effekt bei Frühgeborenen, nicht bei Termingeborenen
- Evidenz für Termingeborene begrenzt
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Metaanalyse in der Zeitschrift American Journal of Perinatology, erschienen am 01.04.2024. Verfasst von Ioannis Bellos und 2 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Experimental Surgery and Surgical Research N.S. Christeas, Division of Surgery, Athens University Medical School, National and Kapodist…. Hauptthemen laut MEDLINE: Positive-Pressure Respiration, Resuscitation. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Themen: Reanimation
Abstract (Originalsprache)
Our objective was to conduct a systematic review and meta-analysis evaluating the effects of administering positive end-expiratory pressure (PEEP) during neonatal resuscitation at birth. Medline, Web of Science, Scopus, Cochrane Central Register of Controlled Trials, and Clinicaltrials.gov databases were systematically searched from inception to 15 December 2020. Randomized controlled trials and cohort studies were held eligible. Studies were included if they compared the administration of PEEP using either a T-piece resuscitator or a self-inflating bag with a PEEP valve versus resuscitation via a self-inflating bag without a PEEP valve. Data were extracted by two reviewers independently. The credibility of evidence was appraised with the Grading of Recommendations, Assessment, Development, and Evaluations approach. Random-effects models were fitted to provide pooled estimates of risk ratio (RR) and 95% confidence intervals (CIs). Overall, 10 studies were included, comprising 4,268 neonates. This included five randomized controlled trials, one quasi-randomized trial, and four cohort studies. The administration of PEEP was associated with significantly lower rates of mortality till discharge (odds ratio [OR]: 0.60, 95% CI: 0.49–0.74, moderate quality of evidence). The association was significant in preterm (OR: 0.57, 95% CI: 0.46–0.69) but not in term (OR: 1.03, 95% CI: 0.52–2.02) neonates. Low-to-moderate quality evidence suggests that providing PEEP during neonatal resuscitation is associated with lower rates of mortality in preterm neonates. Evidence regarding term neonates is limited and inconclusive. Future research is needed to determine the optimal device and shed more light on the long-term effects of PEEP administration during neonatal resuscitation. This study is registered with PROSPERO with registration number: CRD42020219956. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Laboratory of Experimental Surgery and Surgical Research N.S. Christeas, Division of Surgery, Athens University Medical School, National and Kapodistrian University of Athens, Greece.
- Department of Neonatology, Surya Children's Hospital, Mumbai, Maharashtra, India.
- Department of Neonatology, Medanta Hospital, Lucknow, Uttar Pradesh, India.
Zitieren
APA
Bellos, I., Pillai, A., & Pandita, A. (2024). Providing Positive End-Expiratory Pressure during Neonatal Resuscitation: A Meta-analysis. American Journal of Perinatology, 41(06), 690-699. https://doi.org/10.1055/a-1933-7235
Vancouver
Bellos I, Pillai A, Pandita A. Providing Positive End-Expiratory Pressure during Neonatal Resuscitation: A Meta-analysis. American Journal of Perinatology. 2024;41(06):690-699. doi:10.1055/a-1933-7235
BibTeX
@article{Bellos2024,
author = {Bellos, Ioannis and Pillai, Anish and Pandita, Aakash},
title = {Providing Positive End-Expiratory Pressure during Neonatal Resuscitation: A Meta-analysis},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {06},
pages = {690--699},
doi = {10.1055/a-1933-7235}
}
EUVIMED