Use of Pulse Oximetry Pulsatility Index Screening for Critical Congenital Heart Disease
American Journal of Perinatology · 01.05.2024 · 41 (S 01 S 01) · e545-e549
DOI: 10.1055/a-1904-9389 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von Maynard Rasmussen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pediatrics, Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, San Diego, California. Hauptthemen laut MEDLINE: Oximetry, Heart Defects, Congenital, Neonatal Screening. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Objective
This study aimed to compare oximetry data (pre- and postductal oxygen saturation [SpO2], pre- and postductal pulsatility index [PI]) in healthy newborns (≥35 weeks' gestational age) to infants who have critical congenital heart disease (CCHD). Study Design This is a retrospective analysis of data obtained from electronic medical records, recorded as part of routine pulse oximetry screening (POS) for CCHD in infants born between the years 2013 and 2020. Testing was performed at 24 ± 2 hours of life. Data were analyzed to detect differences in pre- and postductal SpO2 and pre- and postductal PI in healthy newborns compared with infants who have CCHD. Newborns were excluded from analysis if they: (1) had a prenatal diagnosis of CCHD in the medical record, (2) had previously been admitted to the neonatal intensive care unit, or (3) had failed POS but were found no CCHD by diagnostic echocardiography.
Results
A total of 88,754 healthy newborns had received POS between the years 2013 and 2020. Of the 88,736 newborn records available for analysis,18 newborns were diagnosed with CCHD. Eight were identified by POS before discharge and 10 were diagnosed after discharge. Infants diagnosed with CCHD by POS had lower pre- and postductal SpO2 compared with normal infants. Their postductal PI was significantly lower. Infants who had CCHD that was not identified by POS had similar pre- and postductal SpO2 values, but their postductal PI was lower. Using a postductal PI cutoff of 1.21 had a receiver operating curve of area under the curve 0.77 (95% confidence interval: 0.672, 0.869) with 74% sensitivity and 61% specificity.
Conclusion
In our large cohort of infants born in San Diego County, the postductal PI is lower in infants with CCHD. Given that PI is routinely displayed on every pulse oximeter and the high morbidity of missed CCHD, PI should be incorporated into routine CCHD screening. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Pediatrics, Neonatal Research Institute, Sharp Mary Birch Hospital for Women & Newborns, San Diego, California.
- Division of Neonatology, Rady Children's Hospital, San Diego, California.
- Department of Pediatrics, University of California, San Diego, La Jolla, San Diego, California.
Zitieren
APA
Rasmussen, M., Suttner, D., Poeltler, D., & Katheria, A. C. (2024). Use of Pulse Oximetry Pulsatility Index Screening for Critical Congenital Heart Disease. American Journal of Perinatology, 41(S 01 S 01), e545-e549. https://doi.org/10.1055/a-1904-9389
Vancouver
Rasmussen M, Suttner D, Poeltler D, Katheria AC. Use of Pulse Oximetry Pulsatility Index Screening for Critical Congenital Heart Disease. American Journal of Perinatology. 2024;41(S 01 S 01):e545-e549. doi:10.1055/a-1904-9389
BibTeX
@article{Rasmussen2024,
author = {Rasmussen, Maynard and Suttner, Denise and Poeltler, Debra and Katheria, Anup C},
title = {Use of Pulse Oximetry Pulsatility Index Screening for Critical Congenital Heart Disease},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {S 01 S 01},
pages = {e545--e549},
doi = {10.1055/a-1904-9389}
}
EUVIMED