Comparison of Assist/Control Ventilation with and without Volume Guarantee in Term or Near-Term Infants
American Journal of Perinatology · 01.05.2024 · 41 (S 01 S 01) · e174-e179
DOI: 10.1055/a-1862-0078 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von Handan Bezirganoglu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology, Department of Pediatrics, University of Health Sciences, Ankara City Hospital, Ankara, Türkiye. Hauptthemen laut MEDLINE: Tidal Volume. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Objectives
This study aimed to compare the effects of volume guarantee (VG) combined with assist/control (AC) ventilation to AC alone on hypocarbia episodes and extubation success in infants born at or near term.
Methods
In this prospective cohort study, infants >34 weeks of gestation at birth, who were born in our hospital supported by synchronized, time-cycled, pressure limited, assist/control ventilation (AC) or assist-controlled VG mechanical ventilation (AC + VG) were included. After admission, infants received either AC or VG + AC using by Leoni Plus ventilator. The ventilation mode was left to the clinician. In the AC group, peak airway pressure was set clinically. In the VG + AC group, desired tidal volume was set at 5 mL/kg, with the ventilator adjusting peak inspiratory pressure to deliver this volume. The study was completed once the patient extubated.
Results
There were 35 patients in each group. Incidence of hypocarbia was lower in the VG + AC compared with AC (%17.1 and 22.8%, respectively) but statistically not significant. Out-of-range partial pressure of carbon dioxide (PCO2) levels were lower in the VG + AC group and it reached borderline statistical significance (p = 0.06). The median extubation time was 70 (42–110) hours in the VG + AC group, 89.5 (48.5–115.5) hours in the AC group, and it did not differ between groups (p = 0.47).
Conclusion
We found combining AC and VG ventilation compared with AC ventilation alone yielded similar hypocarbia episodes and extubation time for infants of >34 gestational weeks with borderline significance lower out-of-range PCO2 incidence. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Neonatology, Department of Pediatrics, University of Health Sciences, Ankara City Hospital, Ankara, Türkiye.
- Division of Neonatology, Trabzon Kanuni Training and Research Hospital, Trabzon, Türkiye.
- Division of Neonatology, Diyarbakir Gazi Yasargil Training and Research Hospital, Diyarbakir, Türkiye.
- Division of Neonatology, Department of Pediatrics, İstanbul Medipol University Medical School, İstanbul, Türkiye.
ORCID-Profile: Handan Bezirganoglu, Mehmet Buyuktiryaki
Zitieren
APA
Bezirganoglu, H., Okur, N., Buyuktiryaki, M., Oguz, S. S., Dizdar, E. A., & Sari, F. N. (2024). Comparison of Assist/Control Ventilation with and without Volume Guarantee in Term or Near-Term Infants. American Journal of Perinatology, 41(S 01 S 01), e174-e179. https://doi.org/10.1055/a-1862-0078
Vancouver
Bezirganoglu H, Okur N, Buyuktiryaki M, Oguz SS, Dizdar EA, Sari FN. Comparison of Assist/Control Ventilation with and without Volume Guarantee in Term or Near-Term Infants. American Journal of Perinatology. 2024;41(S 01 S 01):e174-e179. doi:10.1055/a-1862-0078
BibTeX
@article{Bezirganoglu2024,
author = {Bezirganoglu, Handan and Okur, Nilufer and Buyuktiryaki, Mehmet and Oguz, Serife S and Dizdar, Evrim A and Sari, Fatma N},
title = {Comparison of Assist/Control Ventilation with and without Volume Guarantee in Term or Near-Term Infants},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {S 01 S 01},
pages = {e174--e179},
doi = {10.1055/a-1862-0078}
}
EUVIMED