Light-Emitting Diode (LED) Phototherapy versus Non-LED Phototherapy Devices for Hyperbilirubinemia in Neonates: A Systematic Review and Meta-analysis
American Journal of Perinatology · 01.11.2023 · 40 (15) · 1618-1628
DOI: 10.1055/a-1827-7607 ↗Kurz gefasst
Metaanalyse in der Zeitschrift American Journal of Perinatology, erschienen am 01.11.2023. Verfasst von Rommy H Novoa und 2 weiteren Autor:innen. Beteiligte Einrichtung: High-Risk Pregnancy Unit, Obstetrics and Perinatology Department, Instituto Nacional Materno Perinatal, Lima, Peru. Hauptthemen laut MEDLINE: Hyperbilirubinemia, Neonatal, Hypothermia, Exanthema. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
This review was conducted to evaluate the efficacy of light-emitting diode (LED) phototherapy as compared with the conventional phototherapy in neonates with unconjugated hyperbilirubinemia and their adverse effects. We searched the following databases right from their inception till April, 2021: MEDLINE, EMBASE, Cochrane Library, and LILACS. Randomized clinical trials (RCTs) comparing the LED phototherapy with other light sources, which enrolled newborns (term and preterm) with unconjugated hyperbilirubinemia were included. We included 21 articles in this review. The treatment with the LED light therapy had a lower failure rate as compared with the non-LED one (RR = 0.60, 95% CI: 0.39–0.94). The mean duration of phototherapy was significantly shorter in the group with the LED light source as compared with the one with the non-LED light source (mean difference [hours]: −8.07, 95% CI: −8.45 to −7.68), regardless of the type of non-LED units. However, the rate of bilirubin showed a comparable decline (mean difference [mg/dL/h]: 0.01, 95% CI: −0.00, 0.03) in both the light sources, irrespective of irradiance or distance. No studies reported primary outcomes related to the neurotoxicity effects of hyperbilirubinemia in neonates. The LED light devices caused a significantly higher risk of hypothermia. Neonates were at a lower risk of developing hyperthermia and skin rash with the LED light therapy. Our findings provide support for the use of LED light source phototherapy due to its better clinical efficacy, which is evidenced by its shorter duration and lower rate of treatment failure, as compared with the non-LED light sources. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- High-Risk Pregnancy Unit, Obstetrics and Perinatology Department, Instituto Nacional Materno Perinatal, Lima, Peru.
- Unidad de Análisis y Generación de Evidencias en Salud Pública (UNAGESP), Instituto Nacional de Salud, Ministerio de Salud Lima, Lima, Peru.
- Academic Department of Medical Microbiology, School of Medicine "San Fernando," Universidad Nacional Mayor de San Marcos, Lima, Peru.
ORCID-Profile: Rommy H Novoa
Zitieren
APA
Novoa, R. H., Huaman, K., & Caballero, P. (2023). Light-Emitting Diode (LED) Phototherapy versus Non-LED Phototherapy Devices for Hyperbilirubinemia in Neonates: A Systematic Review and Meta-analysis. American Journal of Perinatology, 40(15), 1618-1628. https://doi.org/10.1055/a-1827-7607
Vancouver
Novoa RH, Huaman K, Caballero P. Light-Emitting Diode (LED) Phototherapy versus Non-LED Phototherapy Devices for Hyperbilirubinemia in Neonates: A Systematic Review and Meta-analysis. American Journal of Perinatology. 2023;40(15):1618-1628. doi:10.1055/a-1827-7607
BibTeX
@article{Novoa2023,
author = {Novoa, Rommy H and Huaman, Karen and Caballero, Patricia},
title = {Light-Emitting Diode (LED) Phototherapy versus Non-LED Phototherapy Devices for Hyperbilirubinemia in Neonates: A Systematic Review and Meta-analysis},
journal = {American Journal of Perinatology},
year = {2023},
volume = {40},
number = {15},
pages = {1618--1628},
doi = {10.1055/a-1827-7607}
}
EUVIMED