Viscoelastic Testing in an Obstetric Population at High Risk of Hemorrhage
American Journal of Perinatology · 01.05.2024 · 41 (07) · 915-923
DOI: 10.1055/a-1788-5025 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift American Journal of Perinatology, erschienen am 01.05.2024. Verfasst von Stephen M Graves und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, The Ohio State University College of Medicine, Columbus, Ohio. Hauptthemen laut MEDLINE: Thrombelastography, Postpartum Hemorrhage. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
Introduction
Rotational thromboelastometry (ROTEM) is a point-of-care viscoelastic test used in trauma for goal-directed transfusion. However, there are limited data on baseline ROTEM parameters in the U.S. obstetric population. Obtaining baseline parameters is a first step in implementing a goal-directed massive transfusion protocol in obstetric hemorrhage.
Objective
Our study aimed to establish pre- and postdelivery baseline parameters in a high-risk obstetric population and determine their association with postpartum hemorrhage (PPH). Study Design Prospective observational study of patients ≥34 weeks' gestation, at high risk of PPH, admitted for delivery. INTEM, EXTEM, FIBTEM, and APTEM assays were performed at the time of admission to labor and delivery and then 2 hours after delivery. Primary outcome was pre- and postdelivery ROTEM parameters among women without PPH. A sample size of 60 women was needed for >90% power to detect at least 50% correlation between pre- and postdelivery assuming a loss of 10% of participants to follow-up.
Results
Of 60 women in the study, 10 (17%) had PPH. Baseline characteristics were not different between those with or without PPH. Pre- and postdelivery ROTEM parameters were not significantly different except for APTEM. None of the patients who had PPH, compared with 4 (10%) of those who did not, had shortened clotting time and higher maximum clot firmness in postdelivery APTEM compared with EXTEM, a pattern suggestive of hyperfibrinolysis (p = 0.4).
Conclusion
In this study, we describe baseline ROTEM parameters in women at high risk of PPH. The majority of patients did not have a ROTEM pattern that is suggestive of hyperfibrinolysis, for which tranexamic acid is thought to be beneficial. Based on our findings, previously established obstetric transfusion thresholds for goal-directed massive transfusion protocols are likely valid for the majority of the obstetric population regardless of the presence of comorbidities or pregnancy complications. Key Points
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Obstetrics and Gynecology, The Ohio State University College of Medicine, Columbus, Ohio.
- Department of Obstetrics and Gynecology, University of Wisconsin Hospital and Clinics, Madison, Wisconsin.
- Department of Anesthesiology, The Ohio State University College of Medicine, Columbus, Ohio.
ORCID-Profile: Stephen M Graves, Maged M Costantine
Zitieren
APA
Graves, S. M., Montemorano, L., Rood, K. M., Costantine, M. M., Fiorini, K., & Cackovic, M. (2024). Viscoelastic Testing in an Obstetric Population at High Risk of Hemorrhage. American Journal of Perinatology, 41(07), 915-923. https://doi.org/10.1055/a-1788-5025
Vancouver
Graves SM, Montemorano L, Rood KM, Costantine MM, Fiorini K, Cackovic M. Viscoelastic Testing in an Obstetric Population at High Risk of Hemorrhage. American Journal of Perinatology. 2024;41(07):915-923. doi:10.1055/a-1788-5025
BibTeX
@article{Graves2024,
author = {Graves, Stephen M and Montemorano, Lauren and Rood, Kara M and Costantine, Maged M and Fiorini, Kasey and Cackovic, Michael},
title = {Viscoelastic Testing in an Obstetric Population at High Risk of Hemorrhage},
journal = {American Journal of Perinatology},
year = {2024},
volume = {41},
number = {07},
pages = {915--923},
doi = {10.1055/a-1788-5025}
}
EUVIMED