EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Tear Evaporation Rate in Subjects with a High Body Mass Index

Ali Abusharha, Gamal A El-Hiti iD, Abdulhadi Alharbi, Raied Fagehi iD, Mana A Alanazi, Ali Alsaqar, Ali M Masmali, Turki Almubrad

Klinische Monatsblätter für Augenheilkunde · 01.03.2023 · 240 (03) · 283-287

DOI: 10.1055/a-1778-4435 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Klinische Monatsblätter für Augenheilkunde, erschienen am 01.03.2023. Verfasst von Ali Abusharha und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia. Hauptthemen laut MEDLINE: Tears, Dry Eye Syndromes. Die Arbeit nennt 51 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

This study evaluated the tear evaporation rate (TER) in subjects with a high body mass index (BMI) and tested the correlation between BMI and dry eye.

Methods

Thirty male subjects aged 18 – 38 years (26.4 ± 4.0 years) with a high BMI (26.4 – 47.0 kg/m2) were enrolled in the study. In addition, a control group of 30 males aged 20 – 36 years (24.0 ± 3.6 years) with a normal BMI (< 25 kg/m2) participated in the study for comparison. Each subject completed the ocular surface disease index (OSDI), followed by the TER measurement using a handheld VapoMeter.

Results

Significant differences (Wilcoxon test; p = 0.002 and 0.001) were found between the median scores of the OSDI (10.3 [3.7] vs. 5.9 [7.2]) and TER (35.5 [13.1] vs. 15.5 [12.8] g/m2 h) in the study and control groups, respectively. The OSDI indicated dry eye in 60.0% of subjects in the study group (n = 18). The TER measurements showed that 76.7% of subjects in the study group (n = 23) had dry eyes. A medium correlation (r = 0.569; p = 0.001) was found between the OSDI scores and TER measurements.

Conclusions

The means of the tear evaporation rate and the ocular surface disease index scores are significantly higher in subjects with a high BMI compared with the control group. Therefore, a high BMI is considered a risk factor for dry eye. The measurement of the tear evaporation rate using a handheld VapoMeter is a simple and rapid method to detect dry eyes in combination with other tools.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TearsDry Eye SyndromesHumansMaleBody Mass Index

Autor:innen und Institutionen

  • Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.

ORCID-Profile: Gamal A El-Hiti, Raied Fagehi

Zitieren

APA

Abusharha, A., El-Hiti, G. A., Alharbi, A., Fagehi, R., Alanazi, M. A., Alsaqar, A., Masmali, A. M., & Almubrad, T. (2023). Evaluation of Tear Evaporation Rate in Subjects with a High Body Mass Index. Klinische Monatsblätter für Augenheilkunde, 240(03), 283-287. https://doi.org/10.1055/a-1778-4435

Vancouver

Abusharha A, El-Hiti GA, Alharbi A, Fagehi R, Alanazi MA, Alsaqar A, et al. Evaluation of Tear Evaporation Rate in Subjects with a High Body Mass Index. Klinische Monatsblätter für Augenheilkunde. 2023;240(03):283-287. doi:10.1055/a-1778-4435

BibTeX
@article{Abusharha2023,
  author = {Abusharha, Ali and El-Hiti, Gamal A and Alharbi, Abdulhadi and Fagehi, Raied and Alanazi, Mana A and Alsaqar, Ali and Masmali, Ali M and Almubrad, Turki},
  title = {Evaluation of Tear Evaporation Rate in Subjects with a High Body Mass Index},
  journal = {Klinische Monatsblätter für Augenheilkunde},
  year = {2023},
  volume = {240},
  number = {03},
  pages = {283--287},
  doi = {10.1055/a-1778-4435}
}
Kostenlos starten →