Interoperator Reliability of Lung Ultrasound during the COVID-19 Pandemic
Ultraschall in der Medizin - European Journal of Ultrasound · 01.02.2023 · 44 (01) · 75-80
DOI: 10.1055/a-1452-8379 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultraschall in der Medizin - European Journal of Ultrasound, erschienen am 01.02.2023. Verfasst von Chiara De Molo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Interventional, Diagnostic and Therapeutic Ultrasound Unit, Department of Medical and Surgical Sciences, Sant'Orsola Malpighi Hospital, Bologna, Ital…. Hauptthemen laut MEDLINE: COVID-19. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Aim
Lung ultrasound (LUS) is a reliable, radiation-free, and bedside imaging technique used to assess several pulmonary diseases. Although COVID-19 is diagnosed with a nasopharyngeal swab, detection of pulmonary involvement is crucial for safe patient discharge. Computed tomography (CT) is currently the gold standard. To treat paucisymptomatic patients, we have implemented a “fast track” pathway in our emergency department, using LUS as a valid alternative. Minimal data is available in the literature about interobserver reliability and the level of expertise needed to perform a reliable examination. Our aim was to assess these. Materials and Methods This was a single-center prospective study. We enrolled 96 patients. 12 lung areas were explored in each patient with a semiquantitative assessment of pulmonary aeration loss in order to obtain the LUS score. Scans were performed by two different operators, an expert and a novice, who were blinded to their colleague’s results.
Results
96 patients were enrolled. The intraclass correlation coefficient (ICC) showed excellent agreement between the expert and the novice operator (ICC 0.975; 0.962–0.983); demographic features (age, sex, and chronic pulmonary disease) did not influence the reproducibility of the method. The ICC was 0.973 (0.950–0.986) in males, 0.976 (0.959–0.986) in females; 0.965 (0.940–0.980) in younger patients (≤ 46 yrs), and 0.973 (0.952–0.985) in older (> 46 yrs) patients. The ICC was 0.967 (0.882–0.991) in patients with pulmonary disease and 0.975 (0.962–0.984) in the other patients. The learning curve showed an increase in interobserver agreement.
Conclusion
Our results confirm the feasibility and reproducibility of the method among operators with different levels of expertise, with a rapid learning curve.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Interventional, Diagnostic and Therapeutic Ultrasound Unit, Department of Medical and Surgical Sciences, Sant'Orsola Malpighi Hospital, Bologna, Italy.
- Emergency department, Azienda Ospedaliero-Universitaria di Bologna Policlinico Sant'Orsola-Malpighi, Bologna, Italy.
Zitieren
APA
De Molo, C., Consolini, S., Salvatore, V., Grignaschi, A., Lanotte, A., Masi, L., Giostra, F., & Serra, C. (2023). Interoperator Reliability of Lung Ultrasound during the COVID-19 Pandemic. Ultraschall in der Medizin - European Journal of Ultrasound, 44(01), 75-80. https://doi.org/10.1055/a-1452-8379
Vancouver
De Molo C, Consolini S, Salvatore V, Grignaschi A, Lanotte A, Masi L, et al. Interoperator Reliability of Lung Ultrasound during the COVID-19 Pandemic. Ultraschall in der Medizin - European Journal of Ultrasound. 2023;44(01):75-80. doi:10.1055/a-1452-8379
BibTeX
@article{DeMolo2023,
author = {De Molo, Chiara and Consolini, Silvia and Salvatore, Veronica and Grignaschi, Alice and Lanotte, Antonella and Masi, Livia and Giostra, Fabrizio and Serra, Carla},
title = {Interoperator Reliability of Lung Ultrasound during the COVID-19 Pandemic},
journal = {Ultraschall in der Medizin - European Journal of Ultrasound},
year = {2023},
volume = {44},
number = {01},
pages = {75--80},
doi = {10.1055/a-1452-8379}
}
EUVIMED