Biocompatibility and clinical implications of removable retainers: A narrative review
Seminars in Orthodontics · 2026-09
DOI: 10.1053/j.sodo.2026.09.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Seminars in Orthodontics, 2026-09. Verfasst von A Campobasso und 3 weiteren Autor:innen. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Removable retention appliances are commonly used for maintaining dental alignment after orthodontic treatment. Alongside conventional acrylic Hawley-type retainers (HRs), thermoformed retainers (TFRs) and, more recently, 3D-printed retainers (3DPRs) have gained popularity among patients and clinicians because of their ease and swiftness of fabrication. However, several concerns have been raised regarding the biocompatibility of retainer materials because of their direct and prolonged contact with oral tissues and the potential release of degradation products during their intraoral aging. This narrative review aims to evaluate and summarize the available evidence on the cytotoxicity of materials used for removable retainers. Although most studies reported slight to moderate cytotoxicity associated with HRs, TFRs, and 3DPRs, as well as low levels of potentially harmful compound release, such as isocyanates, bisphenols, and methacrylate monomers, these findings should not be interpreted as evidence of clinical safety, as direct evidence on removable retainers is limited and predominantly derived from heterogeneous in vitro studies. Particularly for TFRs and 3DPRs, much of the available evidence is indirectly derived from studies on aligner materials, which were considered relevant because of the overlap in the principal polymer classes used for aligners and retainers. Therefore, clinicians should not underestimate the adverse reactions potentially associated with these materials, since the long-term effects of intraoral aging and the risk of cumulative exposure are still unknown. These aspects should be considered especially in vulnerable patients, such as children, pregnant women and allergic patients, for whom alternative retention strategies may be suggested. For 3DPRs, manufacturers' recommendations should be strictly followed during their fabrication, as variations in the manufacturing workflow, particularly during post-curing, may affect the final appliance biocompatibility. In conclusion, HRs, TFRs, and 3DPRs appear to be viable retention strategies; however, given the limited available evidence, these findings should be interpreted with caution, and further longitudinal in vivo studies are needed to ascertain their long-term efficacy and biological impact in vivo.
Zitieren
APA
Campobasso, A., Battista, G., Cattaneo, P., & Cornelis, M. (2026). Biocompatibility and clinical implications of removable retainers: A narrative review. Seminars in Orthodontics. https://doi.org/10.1053/j.sodo.2026.09.002
Vancouver
Campobasso A, Battista G, Cattaneo P, Cornelis M. Biocompatibility and clinical implications of removable retainers: A narrative review. Seminars in Orthodontics. 2026. doi:10.1053/j.sodo.2026.09.002
BibTeX
@article{Campobasso2026,
author = {Campobasso, A and Battista, G and Cattaneo, P.M and Cornelis, M.A},
title = {Biocompatibility and clinical implications of removable retainers: A narrative review},
journal = {Seminars in Orthodontics},
year = {2026},
doi = {10.1053/j.sodo.2026.09.002}
}
EUVIMED