EUVIMEDEUVIMED entdecken
Crossref

Postimpingement instability following reverse shoulder arthroplasty: a parametric finite element analysis

Joshua E. Johnson, Andrea P. Caceres, Donald D. Anderson, Brendan M. Patterson

Seminars in Arthroplasty: JSES · 2021-05 · 31 (1) · 36-44

DOI: 10.1053/j.sart.2020.10.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Seminars in Arthroplasty: JSES, 2021-05. Verfasst von Joshua E. Johnson und 3 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Instability following reverse shoulder arthroplasty is influenced by various factors such as component design, component positioning, and soft tissue tensioning. Patients may achieve glenohumeral motion beyond initial scapular impingement during activities of daily living which could further compound instability. However, instability/subluxation risk postscapular impingement is not well documented. Conventional range of motion analysis tools cannot account for the restraining effect of soft tissues or subluxation risk after impingement. Using a previously validated finite element analysis approach, the purpose of this study was to investigate the effects of glenoid component lateralization and humeral component angle of inclination (AOI), with or without simulated subscapularis repair, on postimpingement subluxation. We hypothesized that lack of subscapularis repair, a valgus humeral component AOI, and glenoid medialization would all result in greater postimpingement instability.

Methods

A FE model of the shoulder including the subscapularis tendon and middle deltoid was created, incorporating a general representation of a commercial reverse shoulder arthroplasty implant placed under the direction of a fellowship-trained shoulder surgeon. The deltoid and subscapularis were tensioned and wrapped around the reconstructed glenohumeral joint prior to simulating motion. Humeral rotations were then prescribed to simulate external rotation (neutral to 50°), extension (neutral to 50°), adduction (neutral to 30°), and abduction (neutral to 90°). The effects of three glenosphere lateralization offsets (2, 4, and 10 mm) and 2 humeral liner angles of inclination (varus-150° and valgus-155°) on subluxation propensities were investigated with and without the subscapularis tendon present.

Results

Simulated subscapularis repair resulted in 21%-34% less postimpingement subluxation. Presence of the subscapularis provided stability over a greater range of abduction. Impingement-free range of motion was similar regardless of the presence or absence of the subscapularis. The valgus AOI resulted in 23% less subluxation during abduction. During other motions however, the valgus AOI resulted in 67%-110% greater postimpingement subluxation (subscapularis present), which further worsened without the subscapularis.

Conclusion

Implant design modifications to improve stability may not be beneficial for all motions, highlighting the importance of directionality when investigating instability. Liner-bone impingement appears to compound instability/subluxation and the subscapularis appears to restrain postimpingement instability. Level of evidence Basic Science Study; Computer Modeling

Zitieren

APA

Johnson, J. E., Caceres, A. P., Anderson, D. D., & Patterson, B. M. (2021). Postimpingement instability following reverse shoulder arthroplasty: a parametric finite element analysis. Seminars in Arthroplasty: JSES, 31(1), 36-44. https://doi.org/10.1053/j.sart.2020.10.005

Vancouver

Johnson JE, Caceres AP, Anderson DD, Patterson BM. Postimpingement instability following reverse shoulder arthroplasty: a parametric finite element analysis. Seminars in Arthroplasty: JSES. 2021;31(1):36-44. doi:10.1053/j.sart.2020.10.005

BibTeX
@article{Johnson2021,
  author = {Johnson, Joshua E. and Caceres, Andrea P. and Anderson, Donald D. and Patterson, Brendan M.},
  title = {Postimpingement instability following reverse shoulder arthroplasty: a parametric finite element analysis},
  journal = {Seminars in Arthroplasty: JSES},
  year = {2021},
  volume = {31},
  number = {1},
  pages = {36--44},
  doi = {10.1053/j.sart.2020.10.005}
}
Kostenlos starten →