Real-time hemodynamic profiling during mitral transcatheter edge-to-edge repair using pulse contour analysis

Sandra Uhle, Mathias H. Konstandin, Benedikt Alt-Epping, Adrian E. Stephan, Benjamin Seybold, Maximilian Dietrich, Florian Uhle, Matthias Eden, Norbert Frey, Markus A. Weigand, Christoph Lichtenstern, Sarah Dehne

Journal of Cardiothoracic and Vascular Anesthesia · 2026-10

DOI: 10.1053/j.jvca.2026.10.046 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026-10. Verfasst von Sandra Uhle und 11 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Heidelberg.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To characterize perioperative hemodynamic response patterns during transcatheter edge-to-edge mitral valve repair (M-TEER) using pulse contour analysis (PCA), and to identify determinants of heterogeneous cardiac output responses following mitral regurgitation (MR) reduction.

Design

Prospective, single-center observational study.

Setting

Single tertiary academic medical center.

Participants

Sixteen consecutive patients undergoing M-TEER with the PASCAL Ace system (Edwards Lifesciences).

Interventions

Continuous PCA monitoring was performed from baseline until 4 h postprocedural alongside periprocedural echocardiography. The primary endpoint was the change in PCA-derived cardiac output (PCA-CO). Secondary endpoints assessed associations between hemodynamic response, procedural success, and ventricular function. Measurements and Main Results Hemodynamic responses varied according to MR reduction and ventricular function. Sustained PCA-CO improvement occurred only with successful MR reduction (≤2+; 24% ± 11%; p = 0.049). Patients with reduced left ventricular ejection fraction showed an early, transient increase in PCA-CO, reaching 108% of baseline (IQR, 86–136%) after first-device implantation (Dunn-adjusted p = 0.035), which was no longer evident at 4 h (p = 0.80). In contrast, patients with preserved ejection fraction showed a delayed, sustained increase at 4 h (14% ± 13%; p = 0.035). Patients with a left ventricular end-diastolic diameter

Förderung

  • University of Heidelberg

Zitieren

APA

Uhle, S., Konstandin, M. H., Alt-Epping, B., Stephan, A. E., Seybold, B., Dietrich, M., Uhle, F., Eden, M., Frey, N., Weigand, M. A., Lichtenstern, C., & Dehne, S. (2026). Real-time hemodynamic profiling during mitral transcatheter edge-to-edge repair using pulse contour analysis. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2026.10.046

Vancouver

Uhle S, Konstandin MH, Alt-Epping B, Stephan AE, Seybold B, Dietrich M, et al. Real-time hemodynamic profiling during mitral transcatheter edge-to-edge repair using pulse contour analysis. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2026.10.046

BibTeX
@article{Uhle2026,
  author = {Uhle, Sandra and Konstandin, Mathias H. and Alt-Epping, Benedikt and Stephan, Adrian E. and Seybold, Benjamin and Dietrich, Maximilian and Uhle, Florian and Eden, Matthias and Frey, Norbert and Weigand, Markus A. and Lichtenstern, Christoph and Dehne, Sarah},
  title = {Real-time hemodynamic profiling during mitral transcatheter edge-to-edge repair using pulse contour analysis},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  doi = {10.1053/j.jvca.2026.10.046}
}
Kostenlos starten →