EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Transesophageal Echocardiography: A Viable Alternative to Intraoperative Doppler Flow Assessment of the Portal Vein in Living Donor Liver Transplantation

Deepak K Tempe, Gaurav Sindwani, Sahithi Latha Ronanki, Sushmitha Dongari, Anil Yadav, Ankit Bhardawaj, Viniyendra Pamecha

Journal of Cardiothoracic and Vascular Anesthesia · 2026

DOI: 10.1053/j.jvca.2026.02.002 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026. Verfasst von Deepak K Tempe und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology and Critical Care, Institute of Liver and Biliary Sciences, New Delhi, India. Electronic address: tempedeepak@hotmail.c…. Hauptthemen laut MEDLINE: Portal Vein, Liver Transplantation, Living Donors, Echocardiography, Transesophageal. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the agreement between portal vein velocity (PVV) measurements obtained using transesophageal echocardiography (TEE) and intraoperative Doppler ultrasound (IOD) in living donor liver transplantation (LDLT), as well as to determine whether TEE can reliably substitute IOD for PVV assessment. DESIGN: A retrospective observational pilot study. SETTING: A single tertiary care university hospital with an established LDLT program. PARTICIPANTS: Twenty-five adult LDLT recipients between April 2023 and March 2024, in whom intraoperative TEE was performed. INTERVENTIONS: Following portal vein anastomosis and graft reperfusion, PVV was measured using both TEE and IOD. MEASUREMENTS AND MAIN RESULTS: Bland-Altman analysis showed a mean bias of -2.16 cm/s (limits of agreement, -11.11 to +6.79 cm/s) with a percentage error of 15%. A strong positive correlation was observed between the TEE and IOD measurements (r = 0.835, p < 0.001). CONCLUSIONS: TEE demonstrates good agreement with IOD for intraoperative PVV measurement in LDLT and offers the advantage of continuous, real-time monitoring (if necessary) without interrupting surgery or breaching sterility. We suggest that PVV assessment by TEE has the potential to replace IOD and should be a part of the assessment whenever TEE is being used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Portal VeinLiver TransplantationLiving DonorsEchocardiography, TransesophagealMonitoring, IntraoperativeEchocardiography, DopplerHumansFemaleMaleRetrospective StudiesPilot ProjectsMiddle AgedAdultBlood Flow Velocity

Stichwörter der Autor:innen

graft reperfusionhemodynamic monitoringintraoperative Doppler ultrasoundliving donorliving donor liver transplantationportal hemodynamicsportal vein velocitytransesophageal echocardiography

Autor:innen und Institutionen

  • Department of Anaesthesiology and Critical Care, Institute of Liver and Biliary Sciences, New Delhi, India. Electronic address: tempedeepak@hotmail.com.
  • Department of Anaesthesiology and Critical Care, Institute of Liver and Biliary Sciences, New Delhi, India.
  • Department of Epidemiology, Institute of Liver and Biliary Sciences, New Delhi, India.
  • Department of Liver Transplantation and HPB Surgery, Institute of Liver and Biliary Sciences,New Delhi, India.

Zitieren

APA

Tempe, D. K., Sindwani, G., Ronanki, S. L., Dongari, S., Yadav, A., Bhardawaj, A., & Pamecha, V. (2026). Transesophageal Echocardiography: A Viable Alternative to Intraoperative Doppler Flow Assessment of the Portal Vein in Living Donor Liver Transplantation. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2026.02.002

Vancouver

Tempe DK, Sindwani G, Ronanki SL, Dongari S, Yadav A, Bhardawaj A, et al. Transesophageal Echocardiography: A Viable Alternative to Intraoperative Doppler Flow Assessment of the Portal Vein in Living Donor Liver Transplantation. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2026.02.002

BibTeX
@article{Tempe2026,
  author = {Tempe, Deepak K and Sindwani, Gaurav and Ronanki, Sahithi Latha and Dongari, Sushmitha and Yadav, Anil and Bhardawaj, Ankit and Pamecha, Viniyendra},
  title = {Transesophageal Echocardiography: A Viable Alternative to Intraoperative Doppler Flow Assessment of the Portal Vein in Living Donor Liver Transplantation},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  doi = {10.1053/j.jvca.2026.02.002}
}
Kostenlos starten →