EUVIMEDEUVIMED entdecken
Crossref

Single-Center Experience with Sonic Estimation of Elasticity via Resonance (SEER)-Guided Hemostasis in Adult Cardiac Surgical Patients

Michael Mazzeffi, Jenna Khan, John McNeil, Jessica Zvara, Susan Walters, Amanda Kleiman, Paul Gallo, Joshua Roach, Robert Thiele, D Keegan Stombaugh, Sachin Mehta, Thomas Floyd und 4 weitere

Journal of Cardiothoracic and Vascular Anesthesia · 2026

DOI: 10.1053/j.jvca.2025.09.031 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2026. Verfasst von Michael Mazzeffi und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University of Virginia School of Medicine, Charlottesville, VA. Electronic address: syy4wa@uvahealth.org. Hauptthemen laut MEDLINE: Cardiac Surgical Procedures, Hemostasis, Elasticity, Monitoring, Intraoperative. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate a single center's experience with intraoperative sonic estimation of elasticity via resonance (SEER)-guided hemostasis management in adult cardiac surgical patients; to explore whether transfusion decisions that were concordant with predefined SEER cutoffs were associated with less bleeding and transfusion in the first 24 hours; and to explore the relationship among SEER cutoffs, intraoperative transfusion, and postoperative chest drain output. DESIGN: A retrospective cohort study. SETTING: A single academic medical center. PARTICIPANTS: Patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) over a 1-year period. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Patient characteristics, surgical details, and SEER measurements prior to separation from CPB were recorded. The primary study outcome was transfusion decision concordance with predefined SEER cutoffs for relevant blood products. Secondary outcomes were 24-hour chest drain output, red blood cell transfusion in the first 24 hours after surgery, and reoperation for bleeding. Overall, 260 of 448 patients (52.0%) had transfusion decisions that were fully concordant with predefined SEER cutoffs. In 448 patients, 83.9% of the platelet transfusion decisions were concordant with the platelet contribution to clot stiffness (PCS) cutoff, 76.3% of cryoprecipitate transfusion decisions were concordant with the fibrinogen contribution to clot stiffness (FCS) cutoff, and 86.6% of plasma transfusion decisions were concordant with the clotting time heparinase (CTH) cutoff. Patients who were transfused concordantly with cutoffs had lower median 24-hour chest drain output (310 mL vs 362 mL), a lower rate of RBC transfusion in the 24 hours after surgery (7.3% vs 15.4%), and fewer reoperations for bleeding (2.7% vs 6.4%) (p < 0.05 for all). Lower PCS and FCS values were associated with more intraoperative blood loss and higher 24-hour chest drain output. CONCLUSIONS: In the majority of cases, providers made transfusion decisions that were concordant with predefined SEER cutoffs. Patients with transfusion decisions that were concordant with SEER cutoffs appeared to have less postoperative bleeding.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Surgical ProceduresHemostasisElasticityMonitoring, IntraoperativeHumansRetrospective StudiesMaleFemaleMiddle AgedAgedCohort StudiesAdultBlood Transfusion

Stichwörter der Autor:innen

bleedingcardiac surgerycoagulationhemostasistransfusion

Autor:innen und Institutionen

  • Department of Anesthesiology, University of Virginia School of Medicine, Charlottesville, VA. Electronic address: syy4wa@uvahealth.org.
  • Department of Pathology, University of Virginia School of Medicine, Charlottesville, VA.
  • Department of Anesthesiology, University of Virginia School of Medicine, Charlottesville, VA.
  • Division of Cardiothoracic Surgery, Department of Surgery, University of Virginia, Charlottesville, VA.

Zitieren

APA

Mazzeffi, M., Khan, J., McNeil, J., Zvara, J., Walters, S., Kleiman, A., Gallo, P., Roach, J., Thiele, R., Stombaugh, D. K., Mehta, S., Floyd, T., Yarboro, L., Beller, J., Kern, J., & Singh, K. (2026). Single-Center Experience with Sonic Estimation of Elasticity via Resonance (SEER)-Guided Hemostasis in Adult Cardiac Surgical Patients. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2025.09.031

Vancouver

Mazzeffi M, Khan J, McNeil J, Zvara J, Walters S, Kleiman A, et al. Single-Center Experience with Sonic Estimation of Elasticity via Resonance (SEER)-Guided Hemostasis in Adult Cardiac Surgical Patients. Journal of Cardiothoracic and Vascular Anesthesia. 2026. doi:10.1053/j.jvca.2025.09.031

BibTeX
@article{Mazzeffi2026,
  author = {Mazzeffi, Michael and Khan, Jenna and McNeil, John and Zvara, Jessica and Walters, Susan and Kleiman, Amanda and Gallo, Paul and Roach, Joshua and Thiele, Robert and Stombaugh, D Keegan and Mehta, Sachin and Floyd, Thomas and Yarboro, Leora and Beller, Jared and Kern, John and Singh, Karen},
  title = {Single-Center Experience with Sonic Estimation of Elasticity via Resonance (SEER)-Guided Hemostasis in Adult Cardiac Surgical Patients},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2026},
  doi = {10.1053/j.jvca.2025.09.031}
}
Kostenlos starten →