Validierungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2025. Verfasst von Lisa Q Rong und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Weill Cornell Medicine, New York, NY. Electronic address: lir9065@med.cornell.edu. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Aorta, Thoracic, Monitoring, Intraoperative, Magnetic Resonance Imaging, Cine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: National Institutes of Health, Foundation for the National Institutes of Health.
Abstract (Originalsprache)
OBJECTIVES: To examine the association and magnitude of agreement between intraoperative transesophageal echocardiography (TEE) and cardiac magnetic resonance imaging (CMR) on aortic diameter measurements, to guide perioperative decision making for ascending aortic aneurysms. DESIGN: This prospective study included patients with an ascending aortic aneurysm undergoing surgical ascending aortic repair using a prosthetic graft between February 2018 and December 2019. Intraoperative TEE in 2-dimensional (2D) and 3-dimensional (3D) views were obtained and assessed relative to preoperative cine-CMR and contrast-enhanced 3D magnetic resonance angiography. SETTING: Weill Cornell Medicine, a single large academic medical center. PARTICIPANTS: Thirty patients undergoing ascending aortic repair using a prosthetic graft (polyethylene terephthalate [Dacron]) without severe aortic valve disease (stenosis or regurgitation). INTERVENTIONS: CMR, TEE, and ascending aortic repair using prosthetic grafts. MEASUREMENTS AND MAIN RESULTS: TEE-derived measurements correlated significantly with CMR at all aortic segments: root (r = 0.94-0.97; p < 0.001 for all), ascending (r = 0.95-0.98; p < 0.001 for all), arch (r = 0.88; p < 0.001), and descending (r = 0.91; p < 0.001). Bland-Altman analyses showed small mean differences between 2D and 3D TEE versus CMR (range, 0.05-0.22 cm and 0.04-0.18 cm, respectively), with narrow limits of agreement at all segments, although TEE underestimated CMR-derived measurements. CONCLUSIONS: This study demonstrates the feasibility of intraoperative TEE to accurately measure aortic diameters in patients with ascending aortic aneurysms. The excellent correlations with CMR and small mean differences with narrow limits of agreement support intraoperative TEE to guide surgical decision making for possible aortic replacement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Weill Cornell Medicine, New York, NY. Electronic address: lir9065@med.cornell.edu.
- Department of Anesthesiology, Weill Cornell Medicine, New York, NY.
- Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York, NY.
Förderung
- National Institutes of Health
- Foundation for the National Institutes of Health
Zitieren
APA
Rong, L. Q., Chun, S., Villar-Calle, P., Reza, M., Leshem, E., Falco, G., Kim, J., Devereux, R. B., & Weinsaft, J. W. (2025). Thoracic Aorta Measurements Using Intraoperative Transesophageal Echocardiography: Validation via Cardiac Magnetic Resonance. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2025.01.038
Vancouver
Rong LQ, Chun S, Villar-Calle P, Reza M, Leshem E, Falco G, et al. Thoracic Aorta Measurements Using Intraoperative Transesophageal Echocardiography: Validation via Cardiac Magnetic Resonance. Journal of Cardiothoracic and Vascular Anesthesia. 2025. doi:10.1053/j.jvca.2025.01.038
BibTeX
@article{Rong2025,
author = {Rong, Lisa Q and Chun, Sena and Villar-Calle, Pablo and Reza, Mahniz and Leshem, Edan and Falco, Giorgia and Kim, Jiwon and Devereux, Richard B and Weinsaft, Jonathan W},
title = {Thoracic Aorta Measurements Using Intraoperative Transesophageal Echocardiography: Validation via Cardiac Magnetic Resonance},
journal = {Journal of Cardiothoracic and Vascular Anesthesia},
year = {2025},
doi = {10.1053/j.jvca.2025.01.038}
}
EUVIMED