EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieOpen Access · CC BY-NC 4.0

Comparison of the Quantra QPlus and ROTEM Goal-Directed Transfusion Protocols in Cardiothoracic Surgery Patients: A Prospective Observational Study

Vera Willers, Jan Royce Linton Krumeich, Anne-Marije Hulshof, Marcus Paulus Buise, Iwan Cornelis Clemens van der Horst, Yvonne Maria Cornelia Henskens, Bas Carolus Theodorus van Bussel, Gerhardus Johannes Albert Josef Maria Kuiper

Journal of Cardiothoracic and Vascular Anesthesia · 2024

DOI: 10.1053/j.jvca.2024.07.046 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2024. Verfasst von Vera Willers und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Treatment, Maastricht University Medical Center, Maastricht, The Netherlands. Electronic address: vera.willers@…. Hauptthemen laut MEDLINE: Thrombelastography, Blood Transfusion. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To compare the designed treatment protocols for the Quantra QPlus and rotational thromboelastometry (ROTEM) with regard to transfusion advice. DESIGN: Prospective observational study. SETTING: Maastricht University Medical Center, The Netherlands. PARTICIPANTS: Adults with elective cardiopulmonary bypass surgery with a ROTEM test. INTERVENTIONS: ROTEM tests were performed postoperatively for standard monitoring of coagulation status and clinical decision making. Simultaneously, a concurrent sample was analyzed for the Quantra QPlus. MEASUREMENTS AND MAIN RESULTS: A total of 100 samples were analyzed using both the ROTEM and Quantra QPlus. Agreement between the transfusion advice for the ROTEM and Quantra QPlus protocols were compared using Cohen κ values for i.a. fibrinogen, platelet concentrates, and fresh frozen plasma (FFP). The agreement between ROTEM and Quantra QPlus was poor for overall transfusion (0.174) and fibrinogen transfusion (0.300). The agreement of cutoff values for fibrinogen clot stiffness for the Quantra QPlus and EXTEM A10 for the ROTEM was poor (0.160). The fibrinogen clot stiffness and FIBTEM A10 had a moderate agreement (0.731). A Cohen κ could not be calculated for the agreement of protamine, thrombocytes, FFP or cutoff values for these transfusions since frequencies included zero in these cases. The Quantra QPlus transfusion protocol advises transfusion in many non-bleeders, adjustments appear to be necessary. In a small group of cases in which clinically relevant blood loss was observed, the Quantra QPlus advised administration of transfusion products, whereas the ROTEM tests did not. CONCLUSION: ROTEM-guided and Quantra-guided transfusion did not correspond in this patient group, and agreement was moderate at best. Specificity and sensitivity for transfusion within protocols were heterogeneous between the methods. More clinical research in high-bleeding risk populations is needed to determine the clinical impact of the different protocols.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThrombelastographyBlood TransfusionHumansProspective StudiesMaleFemaleAgedMiddle AgedCardiac Surgical ProceduresBlood Coagulation Tests

Stichwörter der Autor:innen

Quantra QPlusROTEMbleeding managementcardiopulmonary bypasscardiothoracic surgeryhemostasispoint-of-care testingviscoelastic testing

Autor:innen und Institutionen

  • Department of Anesthesiology and Pain Treatment, Maastricht University Medical Center, Maastricht, The Netherlands. Electronic address: vera.willers@hotmail.com.
  • Department of Intensive Care Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.
  • Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands.
  • Department of Anesthesiology and Pain Treatment, Maastricht University Medical Center, Maastricht, The Netherlands.
  • Cluster for Haemostasis and Transfusion, Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands.

Zitieren

APA

Willers, V., Krumeich, J. R. L., Hulshof, A. M., Buise, M. P., van der Horst, I. C. C., Henskens, Y. M. C., van Bussel, B. C. T., & Kuiper, G. J. A. J. M. (2024). Comparison of the Quantra QPlus and ROTEM Goal-Directed Transfusion Protocols in Cardiothoracic Surgery Patients: A Prospective Observational Study. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2024.07.046

Vancouver

Willers V, Krumeich JRL, Hulshof AM, Buise MP, van der Horst ICC, Henskens YMC, et al. Comparison of the Quantra QPlus and ROTEM Goal-Directed Transfusion Protocols in Cardiothoracic Surgery Patients: A Prospective Observational Study. Journal of Cardiothoracic and Vascular Anesthesia. 2024. doi:10.1053/j.jvca.2024.07.046

BibTeX
@article{Willers2024,
  author = {Willers, Vera and Krumeich, Jan Royce Linton and Hulshof, Anne-Marije and Buise, Marcus Paulus and van der Horst, Iwan Cornelis Clemens and Henskens, Yvonne Maria Cornelia and van Bussel, Bas Carolus Theodorus and Kuiper, Gerhardus Johannes Albert Josef Maria},
  title = {Comparison of the Quantra QPlus and ROTEM Goal-Directed Transfusion Protocols in Cardiothoracic Surgery Patients: A Prospective Observational Study},
  journal = {Journal of Cardiothoracic and Vascular Anesthesia},
  year = {2024},
  doi = {10.1053/j.jvca.2024.07.046}
}
Kostenlos starten →