Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers
Journal of Cardiothoracic and Vascular Anesthesia · 2024
DOI: 10.1053/j.jvca.2024.02.042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiothoracic and Vascular Anesthesia, 2024. Verfasst von Mathias Schemberg und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care Medicine, Herzzentrum Leipzig, Leipzig, Germany. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Echocardiography, Three-Dimensional, Cardiac Surgical Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Themen: Intensivpflege
Abstract (Originalsprache)
OBJECTIVE: To assess the intraoperative use of 3-dimensional transesophageal echocardiography (3D TEE) in cardiac surgical centers, the authors created a survey aimed at evaluating the availability of equipment and the use of 3D TEE for specific surgical and interventional procedures and single-image modalities. The respondents were asked to identify the perceived impact on patient management and current limitations to its routine use. DESIGN: A multiple choice 25-question online survey submitted to the members of the European Association of Cardiothoracic Anesthesia and Intensive Care (EACTAIC) on December 6, 2021, and closed on January 31, 2022. SETTING: An online survey. PARTICIPANTS: Registered EACTAIC members in 2021. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 239 respondents from 44 different countries took part in the survey (27% of the total 903 EACTAIC members). Most respondents (59%) were TEE-certified by the National Board of Echocardiography, European Association of Cardiovascular Imaging (EACVI/EACTAIC), or had a national certificate. Of the respondents, 68% had no formal 3D TEE training. Eight percent of respondents had no 3D machines, whereas 40% had one for each operating room, and 33% had only one for the entire operating room block. 3D TEE was performed most frequently in more than 67% of cases for mitral valve surgery, and in more than 54% of cases for mitral and tricuspid clips, aortic valve, tricuspid valve, and aortic surgery. CONCLUSION: Current guidelines suggest integrating 3D TEE into all comprehensive examinations. The authors' survey reported that intraoperative 3D TEE was used in the majority of mitral valve surgery and only one-half of the other valve surgeries and transcatheter procedures. Its use may be explained by the availability of 3D machines, trained personnel, and limited time to perform TEE in the operating room. Educational initiatives for training in 3D TEE may further increase its routine use.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology and Intensive Care Medicine, Herzzentrum Leipzig, Leipzig, Germany.
- Department of Anaesthesiology and Intensive Care, University Hospitals of Leicester NHS Trust, Leicester, United Kingdom.
- Department of Anesthesiology, Cardiothoracic Anesthesia, University Medical Center Groningen, Groningen, the Netherlands.
- Department of Anesthesiology, King's College, London, United Kingdom.
- Department of Anesthesiology and Intensive Care, Herzzentrum Karlsruhe, Karlsruhe, Germany.
- Department of Anesthesiology and Intensive Care Medicine, Herzzentrum Leipzig, Leipzig, Germany. Electronic address: Massimiliano.Meineri@medizin.uni-leipzig.de.
Zitieren
APA
Schemberg, M., Ender, J., Bence, J., van der Maaten, J., Kunstd, G., Mukherjee, C., & Meineri, M. (2024). Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2024.02.042
Vancouver
Schemberg M, Ender J, Bence J, van der Maaten J, Kunstd G, Mukherjee C, et al. Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers. Journal of Cardiothoracic and Vascular Anesthesia. 2024. doi:10.1053/j.jvca.2024.02.042
BibTeX
@article{Schemberg2024,
author = {Schemberg, Mathias and Ender, Joerg and Bence, Johan and van der Maaten, Joost and Kunstd, Gudrun and Mukherjee, Chirojit and Meineri, Massimiliano},
title = {Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers},
journal = {Journal of Cardiothoracic and Vascular Anesthesia},
year = {2024},
doi = {10.1053/j.jvca.2024.02.042}
}