Development and Validation of a Prediction Model for Estimating 24-Hour Urinary Sodium Excretion Using Spot Urine Samples in Adult Patients
Journal of Renal Nutrition · 2025
DOI: 10.1053/j.jrn.2024.09.004 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Journal of Renal Nutrition, 2025. Verfasst von Miriam Menacho-Roman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Biochemistry Department, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain. Electronic address: miriam.menacho@salud.madrid.org. Hauptthemen laut MEDLINE: Sodium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The measurement of urinary sodium excretion provides valuable information about an individual's sodium balance and can help in the management of various medical conditions. However, the collection of 24-hour urine samples is subject to errors. Spot urine sodium (uNa) measurements are a reliable alternative to 24-hour urine collections for estimating urinary sodium excretion. OBJECTIVE: To assess whether 24-h urinary sodium excretion (24 h uNa) can be estimated from spot samples in adult patients who attend hospital clinics. DESIGN AND METHODS: A cross-sectional study with a development (284 patients) and a validation cohort (229 patients) was conducted at our hospital. A multivariate linear regression model was built which was compared with former models. Concordance analyses and comparison of the ability to correctly classify each patient against a prespecified uNa cutoff value of 130 mmol/24 h were performed, assessed by the C-statistic. RESULTS: The model was well calibrated (slope [95% confidence interval] in internal validation: 0.965 [0.947-0.987], showing good discrimination, and performed robustly in an external validation cohort (slope: 0.811 [0.675-0.946]). The mean bias between the measured and the estimated 24 h uNa by NaRYC was 24.85 mmol/24 h [17.06-32.63]. The NaRYC had the highest values of Pearson coefficient (0.613 P < .0001), accuracy (the percentage of estimated 24 h uNa results within 30% deviation of measured 24 h uNa): 56.8%, and area under the receiver operating characteristic curve: 0.822 [0.766-0.869] as compared to other seven equations. CONCLUSION: Although the mean bias of the results is quite acceptable, the variability observed in the 95% confidence interval makes not recommend the general use of a spot as a substitute of the 24-hour urine in order to estimate the total urine excretion of Na in a single subject basis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Biochemistry Department, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain. Electronic address: miriam.menacho@salud.madrid.org.
- Internal Medicine Department, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain.
- Clinical Biochemistry Department, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain.
- Radiology Department, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain.
Zitieren
APA
Menacho-Roman, M., Fabregate-Fuente, M., Caja-Guayerbas, L., Jiménez-Sánchez, S., Soto, J., & Arribas-Gómez, I. (2025). Development and Validation of a Prediction Model for Estimating 24-Hour Urinary Sodium Excretion Using Spot Urine Samples in Adult Patients. Journal of Renal Nutrition. https://doi.org/10.1053/j.jrn.2024.09.004
Vancouver
Menacho-Roman M, Fabregate-Fuente M, Caja-Guayerbas L, Jiménez-Sánchez S, Soto J, Arribas-Gómez I. Development and Validation of a Prediction Model for Estimating 24-Hour Urinary Sodium Excretion Using Spot Urine Samples in Adult Patients. Journal of Renal Nutrition. 2025. doi:10.1053/j.jrn.2024.09.004
BibTeX
@article{MenachoRoman2025,
author = {Menacho-Roman, Miriam and Fabregate-Fuente, Martin and Caja-Guayerbas, Laura and Jiménez-Sánchez, Sergio and Soto, Javier and Arribas-Gómez, Ignacio},
title = {Development and Validation of a Prediction Model for Estimating 24-Hour Urinary Sodium Excretion Using Spot Urine Samples in Adult Patients},
journal = {Journal of Renal Nutrition},
year = {2025},
doi = {10.1053/j.jrn.2024.09.004}
}
EUVIMED