Fachartikel in der Zeitschrift The Journal of Foot and Ankle Surgery, 2026-06. Verfasst von Cameron Meyer und 4 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic Foot and Ankle Center, 350W. Wilson Bridge Rd, Ste. 200, Worthington, OH 43085, USA. Electronic address: cam.a.meyer@gmail.com. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Total ankle arthroplasty (TAA) has grown in popularity influenced by new implant designs and patient specific options. Tibial fixation options are varied, and modular tibial stems have offered a promise of enhanced mechanical stability of the tibial component. Historically, literature has compared tibia fixation strategies including stemmed implants, peg, cruciate and bar designs; however, modularity in tibial stem length has yet to be explored. Adding to this confusion, fixed post designs often are confused with modular stem designs. PURPOSE: The primary goal of this study was to compare outcomes and complications among 2 and 3 stem piece tibial stemmed INBONE® TAA used for primary ankle arthroplasty. METHODS: The authors retrospectively reviewed a single surgeon operative database (GCB) from 2013 to 2024. Patient demographics, complications, and replacement longevity was recorded. RESULTS: We found the 2 stem group return to operating room time pertaining to TAA revision was significantly sooner compared to the 3 stem group (p = 0.046). The number of complications was deemed not significant in the 2 stem group requiring operative intervention compared to the 3 stem group (p = 0.057). CONCLUSION: Variable stem length appears to impact long term sustainability of total ankle replacement. More prospective studies are necessary comparing tibial stem length and risk of failure and complication.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopedic Foot and Ankle Center, 350W. Wilson Bridge Rd, Ste. 200, Worthington, OH 43085, USA. Electronic address: cam.a.meyer@gmail.com.
- Orthopedic Foot and Ankle Center, 350W. Wilson Bridge Rd, Ste. 200, Worthington, OH 43085, USA.
- Foot and Ankle Surgeon, Carle McLean County Orthopedics, 1111 Trinity Ln Suite 111, Bloomington, IL 61704, USA.
- Foot and Ankle Surgeon; Orthopedic Foot and Ankle Center, 350W. Wilson Bridge Rd, Ste. 200, Worthington, OH 43085, USA.
Zitieren
APA
Meyer, C., Kim, J. Y., Martinez, O., Christie, L. M., & Berlet, G. (2026). Longevity of 2 piece vs 2+ piece stemmed total ankle replacement; is there an optimal length?. The Journal of Foot and Ankle Surgery. https://doi.org/10.1053/j.jfas.2026.06.021
Vancouver
Meyer C, Kim JY, Martinez O, Christie LM, Berlet G. Longevity of 2 piece vs 2+ piece stemmed total ankle replacement; is there an optimal length?. The Journal of Foot and Ankle Surgery. 2026. doi:10.1053/j.jfas.2026.06.021
BibTeX
@article{Meyer2026,
author = {Meyer, Cameron and Kim, Jae Yoon and Martinez, Orlando and Christie, Lauren M and Berlet, Gregory},
title = {Longevity of 2 piece vs 2+ piece stemmed total ankle replacement; is there an optimal length?},
journal = {The Journal of Foot and Ankle Surgery},
year = {2026},
doi = {10.1053/j.jfas.2026.06.021}
}
EUVIMED