Numerical investigation of multi-level metal anti-wear grill configurations for erosion mitigation in a 110 MW CFB boiler
MATEC Web of Conferences · 2026 · 423 · 01002
DOI: 10.1051/matecconf/202642301002 ↗Kurz gefasst
Fachartikel in der Zeitschrift MATEC Web of Conferences, online erschienen am 12.08.2026. Verfasst von Triyogi Yuwono und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Waterwall tube erosion induced by particle wall-flow is one of the major reliability problems in circulating fluidized bed (CFB) boilers and frequently causes tube leakage during operation. The installation of anti-wear devices on the waterwall has been widely applied as an effective method to reduce particle-induced erosion. In this work, multi-level triangular anti-wear grill configurations were numerically investigated by comparing the erosion behavior of local waterwall regions in a 110 MW CFB boiler using computational fluid dynamics (CFD). Four grill configurations were evaluated by varying grill inclination angle and inter-grill spacing. The results show that grill installation effectively reduces erosion by interrupting the descending near-wall particle flow and redirecting particles toward the furnace core, thereby reducing direct particle impingement on the waterwall. The grill inclination angle significantly affects erosion distribution, where the 60° configuration provides lower combined average erosion and lower peak erosion than the 30° configuration due to reduced particle rebound and more stable flow redirection. The inter-grill spacing also influences downstream erosion recovery, where the 1.0 m spacing delays gas-solid flow reattachment to the wall and reduces erosion in the nearto mid-recovery regions compared with the 0.8 m spacing. Based on the combined erosion performance, the triangular anti-wear grill with a 60° inclination angle and 1.0 m interspacing is recommended as the optimum configuration for minimizing waterwall erosion in the investigated CFB boiler.
Zitieren
APA
Yuwono, T., Maulana, A., Syaifudin, A., & Pangastuti, D. (2026). Numerical investigation of multi-level metal anti-wear grill configurations for erosion mitigation in a 110 MW CFB boiler. MATEC Web of Conferences, 423, 01002. https://doi.org/10.1051/matecconf/202642301002
Vancouver
Yuwono T, Maulana A, Syaifudin A, Pangastuti D. Numerical investigation of multi-level metal anti-wear grill configurations for erosion mitigation in a 110 MW CFB boiler. MATEC Web of Conferences. 2026;423:01002. doi:10.1051/matecconf/202642301002
BibTeX
@article{Yuwono2026,
author = {Yuwono, Triyogi and Maulana, Ahmad and Syaifudin, Achmad and Pangastuti, Diah},
title = {Numerical investigation of multi-level metal anti-wear grill configurations for erosion mitigation in a 110 MW CFB boiler},
journal = {MATEC Web of Conferences},
year = {2026},
volume = {423},
pages = {01002},
doi = {10.1051/matecconf/202642301002}
}
EUVIMED