A Novel Emergency Technique to Bypass a Failed Quest MPS Cardioplegia System While on Bypass: A Simulation-Based Study
The Journal of ExtraCorporeal Technology · 24.08.2026
DOI: 10.1051/ject/2026031 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of ExtraCorporeal Technology, online erschienen am 24.08.2026. Verfasst von Ke'Shawna Gallien und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Cardioplegia is important for myocardial protection during cardiac surgery, allowing a motionless, bloodless field while preventing ischemic injury to the heart . There have been various formulations and techniques to ensure myocardial protection. Current delivery methods include antegrade delivery via the aortic root and retrograde delivery via the coronary sinus. In addition, there are various solution types, delivery temperatures, and equipment. The Quest Myocardial Protection System (MPS) 3 is a device designed to deliver various types of cardioplegia formulations safely at various routes. However, malfunctions of the system have been reported in the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA), prompting this research topic. The Quest MPS 3 has a bypass line in case the system becomes unstable or there is a battery failure. This project aimed to design and test an Emergency Switch Over Line (ESOL) for the Quest MPS 3, modeled after the Parallel Replacement of oxygenator that is not transferring oxygen (PRONTO) line used in oxygenator change-outs. The ESOL is designed to ensure uninterrupted cardioplegia delivery that is bubble-free, maintains temperature, maintains flow, and has pressure monitoring, and the delivery of cardioplegia can be tailored to initiation protocols with the use of a potassium handheld syringe chart. The development of the ESOL, its protocol, and handheld potassium delivery chart serves as a reliable solution to myocardial protection in the simulation lab.
Zitieren
APA
Gallien, K., Fisher, R., Giddens, B., Jeter, L., Ward, C. T., White, B. D., & McNair, E. (2026). A Novel Emergency Technique to Bypass a Failed Quest MPS Cardioplegia System While on Bypass: A Simulation-Based Study. The Journal of ExtraCorporeal Technology. https://doi.org/10.1051/ject/2026031
Vancouver
Gallien K, Fisher R, Giddens B, Jeter L, Ward CT, White BD, et al. A Novel Emergency Technique to Bypass a Failed Quest MPS Cardioplegia System While on Bypass: A Simulation-Based Study. The Journal of ExtraCorporeal Technology. 2026. doi:10.1051/ject/2026031
BibTeX
@article{Gallien2026,
author = {Gallien, Ke'Shawna and Fisher, Raylynn and Giddens, Benjamin and Jeter, Leslie and Ward, Ceressa T. and White, Brian D. and McNair, Erick},
title = {A Novel Emergency Technique to Bypass a Failed Quest MPS Cardioplegia System While on Bypass: A Simulation-Based Study},
journal = {The Journal of ExtraCorporeal Technology},
year = {2026},
doi = {10.1051/ject/2026031}
}
EUVIMED