EUVIMEDEUVIMED entdecken
Crossref

Is Conventional Venous Cannulation Enough? Improved Drainage with a Dual Cannulation Technique During Coronary Artery Bypass Grafting Procedures

James Matthew Beck, Christine Chan, Kenmond Fung, Sophie Celentano, Isaac George, Koji Takeda

The Journal of ExtraCorporeal Technology · 05.07.2026

DOI: 10.1051/ject/2026027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of ExtraCorporeal Technology, online erschienen am 05.07.2026. Verfasst von James Matthew Beck und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Effective venous drainage during cardiopulmonary bypass (CPB) is essential for maintaining hemodynamic stability and optimizing surgical exposure during coronary artery bypass grafting (CABG). Single right atrial (RA) cannulation may be susceptible to impaired venous return during cardiac manipulation, leading to increased central venous pressure (CVP) and vasopressor requirements, potentially contributing to postoperative morbidity. In this study, we evaluate whether dual RA-superior vena cava (SVC) cannulation compared to standard RA cannulation improves intraoperative perfusion and hemodynamic parameters.

Methods

We performed a retrospective pilot analysis of adult patients undergoing elective CABG between June 2024 and February 2025. We compared outcomes in the following cohorts: A) a single surgeon after adoption of dual RA-SVC cannulation, versus B) all surgeons performing RA-only cannulation. Primary outcomes included mean aortic cross-clamp (AOXCL) cardiac index (CI), CVP, maximum CVP, and intraoperative phenylephrine requirements. Secondary analysis evaluated hematocrit, blood pressure, total CPB duration, and other operative parameters. F-tests were conducted to properly account for sample variance, followed by comparative analyses using appropriate two-sample t-tests.

Results

A total of 102 patients were identified and analyzed. In Cohort A, a single surgeon performed 23 cases employing RA-SVC cannulation. In cohort B, 79 operations using RA-only cannulation were evaluated. Dual-cannulation in Cohort A’s cases was associated with statistically significant greater mean CI (p=0.025), lower mean CVP (p

Zitieren

APA

Beck, J. M., Chan, C., Fung, K., Celentano, S., George, I., & Takeda, K. (2026). Is Conventional Venous Cannulation Enough? Improved Drainage with a Dual Cannulation Technique During Coronary Artery Bypass Grafting Procedures. The Journal of ExtraCorporeal Technology. https://doi.org/10.1051/ject/2026027

Vancouver

Beck JM, Chan C, Fung K, Celentano S, George I, Takeda K. Is Conventional Venous Cannulation Enough? Improved Drainage with a Dual Cannulation Technique During Coronary Artery Bypass Grafting Procedures. The Journal of ExtraCorporeal Technology. 2026. doi:10.1051/ject/2026027

BibTeX
@article{Beck2026,
  author = {Beck, James Matthew and Chan, Christine and Fung, Kenmond and Celentano, Sophie and George, Isaac and Takeda, Koji},
  title = {Is Conventional Venous Cannulation Enough? Improved Drainage with a Dual Cannulation Technique During Coronary Artery Bypass Grafting Procedures},
  journal = {The Journal of ExtraCorporeal Technology},
  year = {2026},
  doi = {10.1051/ject/2026027}
}
Kostenlos starten →