EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 4.0

Endo-aortic balloon occlusion for reoperative minimally invasive mitral valve replacement on intra-aortic balloon pump: a case report

Jenna L Cornibe, Vivek Patel, Austin Erney

The Journal of ExtraCorporeal Technology · 2025

DOI: 10.1051/ject/2025023 ↗

Kurz gefasst

Fallbericht in der Zeitschrift The Journal of ExtraCorporeal Technology, 2025. Verfasst von Jenna L Cornibe und 2 weiteren Autor:innen. Beteiligte Einrichtung: Jupiter Medical Center, 1210 S Old Dixie Hwy, Jupiter, FL 33458, USA - Perfusion Services, Epic Specialty Staffing, 2250 McGregor Blvd Suite 3300, Fo…. Hauptthemen laut MEDLINE: Intra-Aortic Balloon Pumping, Balloon Occlusion, Minimally Invasive Surgical Procedures, Heart Valve Prosthesis Implantation. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Minimally invasive approaches are the future of cardiac surgery. Coupled with that are devices such as endo-aortic balloon occlusion (EABO) which allow the success of such procedures. EABO has also proven invaluable in high-risk or reoperative cases. We report a severely high-risk patient who presented for reoperative minimally invasive mitral valve replacement with an intra-aortic balloon pump (IABP) and multiple high-dose vasopressors. The EABO was utilized over a transthoracic cross clamp (TCC). With careful maneuvering upon ascent into the aorta, the deflated endoballoon easily passed beyond the deflated IABP balloon under transesophageal echocardiogram (TEE) guidance. After completion of arrest, surgical placement of the bioprosthetic valve, and spontaneous return of cardiac rhythm once EABO was completed, the deflated endoballoon was carefully retracted back down through the aorta past the deflated IABP balloon. The integrity of the IABP balloon remained intact and was able to resume function once cardiopulmonary bypass (CPB) was terminated. We found that EABO was a safe and effective alternative technique for aortic occlusion in our patient supported on IABP with previous sternotomy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intra-Aortic Balloon PumpingBalloon OcclusionMinimally Invasive Surgical ProceduresHeart Valve Prosthesis ImplantationMitral ValveHumansReoperationMaleTreatment Outcome

Stichwörter der Autor:innen

EABOEndo-aortic balloon occlusionEndoballoonIABPMinimally invasive

Autor:innen und Institutionen

  • Jupiter Medical Center, 1210 S Old Dixie Hwy, Jupiter, FL 33458, USA - Perfusion Services, Epic Specialty Staffing, 2250 McGregor Blvd Suite 3300, Fort Myers, FL 33901, USA.
  • Jupiter Medical Center, 1210 S Old Dixie Hwy, Jupiter, FL 33458, USA.

Zitieren

APA

Cornibe, J. L., Patel, V., & Erney, A. (2025). Endo-aortic balloon occlusion for reoperative minimally invasive mitral valve replacement on intra-aortic balloon pump: a case report. The Journal of ExtraCorporeal Technology. https://doi.org/10.1051/ject/2025023

Vancouver

Cornibe JL, Patel V, Erney A. Endo-aortic balloon occlusion for reoperative minimally invasive mitral valve replacement on intra-aortic balloon pump: a case report. The Journal of ExtraCorporeal Technology. 2025. doi:10.1051/ject/2025023

BibTeX
@article{Cornibe2025,
  author = {Cornibe, Jenna L and Patel, Vivek and Erney, Austin},
  title = {Endo-aortic balloon occlusion for reoperative minimally invasive mitral valve replacement on intra-aortic balloon pump: a case report},
  journal = {The Journal of ExtraCorporeal Technology},
  year = {2025},
  doi = {10.1051/ject/2025023}
}
Kostenlos starten →