EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Floating photovoltaics: modelled and experimental operating temperatures and the impact of wind speed and direction

Vilde Stueland Nysted, Dag Lindholm, Josefine Selj, Torunn Kjeldstad

EPJ Photovoltaics · 2024 · 15 · 23

DOI: 10.1051/epjpv/2024020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EPJ Photovoltaics, online erschienen am 17.06.2024. Verfasst von Vilde Stueland Nysted und 3 weiteren Autor:innen. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Norges Forskningsråd.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Floating photovoltaics (FPV) is rapidly emerging as a promising alternative to ground-mounted PV (GPV) where available land area is scarce or expensive. Improved cooling has often been reported as a benefit of FPV, as cell temperature is an important parameter for the performance of a PV system. However, more recent literature shows that the cooling effect depends strongly on FPV technology and that it is not always superior to that of open rack GPV systems. There is still a need for more information on how to estimate cell temperatures for FPV systems, and how to consider the influence of various environmental factors such as wind speed and direction. Operating cell temperature may be estimated with the PVsyst model, where heat loss coefficients ( U -values) denote the heat transfer capabilities of the PV system. In this work, cell temperatures and U -values for a small footprint FPV system with east-west orientation and a 15° tilt located in Sri Lanka are studied using both module temperature measurements and computational fluid dynamics (CFD) modelling. CFD modelling allows for investigating the influence of both wind speed and direction on cell temperatures, as well as to look at the distribution of cell temperatures within the system under different wind conditions. Calculations based on measurements give U c = 22.6 W/m 2 K and U v = 4.9 Ws/m 3 K and correlate well with CFD calculations. We also show that wind direction, system configuration and sensor placement influence the estimated U -values, complicating the use of tabulated values for any given technology.

Förderung

  • Norges Forskningsråd

Zitieren

APA

Nysted, V. S., Lindholm, D., Selj, J., & Kjeldstad, T. (2024). Floating photovoltaics: modelled and experimental operating temperatures and the impact of wind speed and direction. EPJ Photovoltaics, 15, 23. https://doi.org/10.1051/epjpv/2024020

Vancouver

Nysted VS, Lindholm D, Selj J, Kjeldstad T. Floating photovoltaics: modelled and experimental operating temperatures and the impact of wind speed and direction. EPJ Photovoltaics. 2024;15:23. doi:10.1051/epjpv/2024020

BibTeX
@article{Nysted2024,
  author = {Nysted, Vilde Stueland and Lindholm, Dag and Selj, Josefine and Kjeldstad, Torunn},
  title = {Floating photovoltaics: modelled and experimental operating temperatures and the impact of wind speed and direction},
  journal = {EPJ Photovoltaics},
  year = {2024},
  volume = {15},
  pages = {23},
  doi = {10.1051/epjpv/2024020}
}
Kostenlos starten →