Bioengineered self-healing concrete for corrosion resilience: Long-term evaluation of Bacillus subtilis mediated crack repair

Pinta Astuti, Angga Jordi Wisnu Nouvaldi, Muhammad Rafli Syahputra, Aqila Naja Aria Putri, Amanda Nurrizky, Nur Angga Dwi Maulani, Adhitya Yoga Purnama

BIO Web of Conferences · 2026 · 265 · 02003

DOI: 10.1051/bioconf/202626502003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BIO Web of Conferences, online erschienen am 17.11.2026. Verfasst von Pinta Astuti und 6 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bio-patch repair using Bacillus subtilis shows promise for corrosion control in geopolymer mortar, but most evaluations end within weeks or months, leaving longer-term performance largely untested. This study evaluates Bacillus subtilis at 1% and 1.5% concentrations combined with fly ash and rice husk ash (RHA) geopolymer mortar over 570 days, on specimens already 1.5 years old. Eight mix variations (0-12% RHA) were assessed through Half-cell potential (HCP) monitoring, physical-property testing, self-healing observation, carbonation depth, destructive actual-corrosion and mass-loss testing, and SEM-FTIR microstructural analysis. Variation 3 (90% fly ash, 9% RHA, 1% Bacillus subtilis) sustained an average HCP of -190.94 mV, within the ASTM C876-15 low-corrosion-probability threshold, and achieved the highest self-healing effectiveness, 91.43%, closing cracks from 0.7 mm to 0.06 mm within 14 days through calcite biomineralization. Variation 5 (98.5% fly ash, 1.5% Bacillus subtilis) gave the highest compressive strength, 29.81 MPa, and the shallowest carbonation depth, while variation 8 (86.5% fly ash, 12% RHA, 1.5% Bacillus subtilis) showed the lowest mass loss, 1.32%, and smallest corroded area, 26.36%, at 5 cm cover. Cover thickness influenced corrosion extent more consistently than mix composition, and 1.5% Bacillus subtilis outperformed 1% on strength and durability, while 9% RHA balanced structural stability with crack-closure support. These results indicate that Bacillus subtilis-mediated bio-patch repair with fly ash-RHA geopolymer mortar remains a durable, sustainable corrosion-control strategy after 1.5 years of in-service exposure.

Zitieren

APA

Astuti, P., Nouvaldi, A. J. W., Syahputra, M. R., Putri, A. N. A., Nurrizky, A., Maulani, N. A. D., & Purnama, A. Y. (2026). Bioengineered self-healing concrete for corrosion resilience: Long-term evaluation of Bacillus subtilis mediated crack repair. BIO Web of Conferences, 265, 02003. https://doi.org/10.1051/bioconf/202626502003

Vancouver

Astuti P, Nouvaldi AJW, Syahputra MR, Putri ANA, Nurrizky A, Maulani NAD, et al. Bioengineered self-healing concrete for corrosion resilience: Long-term evaluation of Bacillus subtilis mediated crack repair. BIO Web of Conferences. 2026;265:02003. doi:10.1051/bioconf/202626502003

BibTeX
@article{Astuti2026,
  author = {Astuti, Pinta and Nouvaldi, Angga Jordi Wisnu and Syahputra, Muhammad Rafli and Putri, Aqila Naja Aria and Nurrizky, Amanda and Maulani, Nur Angga Dwi and Purnama, Adhitya Yoga},
  title = {Bioengineered self-healing concrete for corrosion resilience: Long-term evaluation of Bacillus subtilis mediated crack repair},
  journal = {BIO Web of Conferences},
  year = {2026},
  volume = {265},
  pages = {02003},
  doi = {10.1051/bioconf/202626502003}
}
Kostenlos starten →