EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Harmonic Response Characteristics of Loss Current in 10 kV XLPE Cables Under Conductor Spike Defects

Xinsen Yang, Guowei Guo, Zeli Xi, Cong Chen

The Journal of Engineering · 2026-01 · 2026 (1)

DOI: 10.1049/tje2.70233 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Engineering, online erschienen am 04.09.2026. Verfasst von Xinsen Yang und 3 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cables are widely used in renewable‐energy stations, and the reliable assessment of their insulation condition is essential for safe and stable system operation. In this study, the harmonic characteristics of the loss current in 10 kV XLPE cables containing conductor spike defects were investigated through simulation and experimental analysis. Based on the bipolar charge transport model, the nonlinear conductivity behavior of XLPE under high electric fields was analyzed, and the effects of tip curvature radius, defect location, and electrode spacing on the loss current and conductivity characteristics were evaluated. The results show that conductor spike defects cause severe local electric‐field distortion, which induces periodic fluctuations in insulation conductivity and distorts the loss‐current waveform, leading to the appearance of higher‐order harmonics. The harmonic components are dominated by the 3rd and 5th harmonics, and their contribution ratios vary with defect severity and location. As the defect becomes more severe, the amplitude and total harmonic distortion of the loss current, as well as the conductivity distortion rate, all increase significantly. Moreover, defects located at the conductor core produce higher distortion levels than those located at the shielding layer. A representative experimental condition supports the principal 3rd‐ and 5th‐harmonic signatures predicted by the simulation, providing a physical basis for further investigation of loss‐current harmonics as comparative indicators of conductor spike defects in 10 kV XLPE cables.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yang, X., Guo, G., Xi, Z., & Chen, C. (2026). Harmonic Response Characteristics of Loss Current in 10 kV XLPE Cables Under Conductor Spike Defects. The Journal of Engineering, 2026(1). https://doi.org/10.1049/tje2.70233

Vancouver

Yang X, Guo G, Xi Z, Chen C. Harmonic Response Characteristics of Loss Current in 10 kV XLPE Cables Under Conductor Spike Defects. The Journal of Engineering. 2026;2026(1). doi:10.1049/tje2.70233

BibTeX
@article{Yang2026,
  author = {Yang, Xinsen and Guo, Guowei and Xi, Zeli and Chen, Cong},
  title = {Harmonic Response Characteristics of Loss Current in 10 kV XLPE Cables Under Conductor Spike Defects},
  journal = {The Journal of Engineering},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1049/tje2.70233}
}
Kostenlos starten →