Potential of Dynamic Thermal Rating of Flexible Busbars in Power Substations

Jozef Bendík, Matej Cenký, Anton Beláň

The Journal of Engineering · 2026-01 · 2026 (1)

DOI: 10.1049/tje2.70229 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Engineering, online erschienen am 04.09.2026. Verfasst von Jozef Bendík und 2 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study examines the ambient‐adjusted rating (AAR) of flexible busbar conductors in power substations, a simple form of dynamic thermal rating that is directly applicable with existing meteorological infrastructure. One year of weather data measured at a Slovak transmission substation was used to rate the ACSR 758‐AL1/43‐ST1A conductor with two AAR models: M1, with variable ambient temperature and constant solar irradiation, and M2, with both quantities variable. The resulting dynamic ratings are compared with the static ratings of four Central European countries. The median rating of model M2 is 39% above the Slovak static value at the 80 conductor temperature limit, with an overload potential index of 1.91. The revision extends the original analysis in three directions requested by practice: a wind‐speed sensitivity study (0.2–2.0 m/s), a full dynamic rating model M3 that uses the measured wind speed, and a statistical assessment covering seasonal variability, rating distributions, thermal risk at static‐rating loading, and measurement uncertainty. Model M3 reaches a median of 1851 A, 24% above M2, which quantifies the capacity given up by the conservative wind assumption of the AAR. A thermal‐risk analysis shows that continuous loading at the Slovak static rating never brought the conductor above 77 during the analysed year. The results support AAR as a low‐cost first step for both transmission and distribution system operators, with straightforward validation through conductor temperature monitoring in the confined substation environment.

Zitieren

APA

Bendík, J., Cenký, M., & Beláň, A. (2026). Potential of Dynamic Thermal Rating of Flexible Busbars in Power Substations. The Journal of Engineering, 2026(1). https://doi.org/10.1049/tje2.70229

Vancouver

Bendík J, Cenký M, Beláň A. Potential of Dynamic Thermal Rating of Flexible Busbars in Power Substations. The Journal of Engineering. 2026;2026(1). doi:10.1049/tje2.70229

BibTeX
@article{Bendk2026,
  author = {Bendík, Jozef and Cenký, Matej and Beláň, Anton},
  title = {Potential of Dynamic Thermal Rating of Flexible Busbars in Power Substations},
  journal = {The Journal of Engineering},
  year = {2026},
  volume = {2026},
  number = {1},
  doi = {10.1049/tje2.70229}
}
Kostenlos starten →