EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Method for Locating Partial Discharge in Transformer Based on the Optical and Electric Collaborative Acoustic Sensing Technology

Anqiang Lv, Xinpeng Li, Jing Wang, Zhong Li

IET Science, Measurement & Technology · 2026-01 · 20 (1)

DOI: 10.1049/smt2.70069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IET Science, Measurement & Technology, online erschienen am 13.05.2026. Verfasst von Anqiang Lv und 3 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In existing ultrasonic localization methods for transformer partial discharge, three‐dimensional sensor array deployment requires a large number of sensors, resulting in a high cost and unfavourable spatial topology. In contrast, two‐dimensional array deployment exhibits low sensitivity to the vertical position of partial discharge sources and is prone to multiple solutions and local optimal solutions under ambiguous boundary conditions. To address these limitations, this paper integrates the advantages of both three‐dimensional and two‐dimensional array deployments while avoiding their respective drawbacks. Proposing a transformer partial discharge localization method based on optical and electric collaborative acoustic sensing technology. Firstly, a collaborative deployment scheme for distributed optical fibre sensing and electronic acoustic sensing is investigated. Subsequently, a hierarchical fusion localization strategy is designed, in which spatial localization is achieved using optical signals followed by precise localization using electrical signals. Finally, a partial discharge experimental platform is established and both types of sensors are deployed. Partial discharge localization is performed based on the acquired optical and electrical signals, and comparative experiments are conducted with existing localization methods. The results demonstrate that the proposed method achieves a localization error of less than 7.12 cm with a localization time of 0.95 s, without the occurrence of local optimal solutions or multiple solutions. Compared with existing partial discharge localization techniques, the proposed method exhibits higher accuracy and good feasibility. By constraining the solution space spatially, it effectively avoids local optimal solutions during nonlinear equation solving, thereby fully validating its effectiveness in transformer partial discharge localization.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Lv, A., Li, X., Wang, J., & Li, Z. (2026). A Method for Locating Partial Discharge in Transformer Based on the Optical and Electric Collaborative Acoustic Sensing Technology. IET Science, Measurement & Technology, 20(1). https://doi.org/10.1049/smt2.70069

Vancouver

Lv A, Li X, Wang J, Li Z. A Method for Locating Partial Discharge in Transformer Based on the Optical and Electric Collaborative Acoustic Sensing Technology. IET Science, Measurement & Technology. 2026;20(1). doi:10.1049/smt2.70069

BibTeX
@article{Lv2026,
  author = {Lv, Anqiang and Li, Xinpeng and Wang, Jing and Li, Zhong},
  title = {A Method for Locating Partial Discharge in Transformer Based on the Optical and Electric Collaborative Acoustic Sensing Technology},
  journal = {IET Science, Measurement & Technology},
  year = {2026},
  volume = {20},
  number = {1},
  doi = {10.1049/smt2.70069}
}
Kostenlos starten →