Explainable Early Fault Detection in Wind Turbine Generators Using Only SCADA Data From an Operational Wind Farm
IET Renewable Power Generation · 2026-01 · 20 (1)
DOI: 10.1049/rpg2.70316 ↗Kurz gefasst
Fachartikel in der Zeitschrift IET Renewable Power Generation, online erschienen am 22.07.2026. Verfasst von Kevin Barrera und 1 weiteren Autor:innen. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This work presents a methodology for early fault detection in wind turbine generators using SCADA data from eight turbines, one of which failed from winding overheating. The methodology estimates healthy phase temperatures to establish a baseline, detecting faults via deviations from measurements. SCADA time series are transformed into Gramian angular field (GAF) images, allowing convolutional neural networks (CNNs) to capture complex temporal dependencies. To address computational cost, a two‐stage approach is proposed: first, a global model is trained on data from multiple turbines. Second, a fine‐tuning process adapts the model to each turbine, reducing cost and enabling efficient adaptation. Explainability techniques (integrated gradients) identify influential variables. The global model achieves a mean absolute error (MAE) of 2.016 and MSE of 8.279. Fine‐tuning improves performance, reducing the MAE to 1.479 and MSE to 4.299. The method offers an efficient and scalable solution for predictive maintenance.
Zitieren
APA
Barrera, K., & Vidal, Y. (2026). Explainable Early Fault Detection in Wind Turbine Generators Using Only SCADA Data From an Operational Wind Farm. IET Renewable Power Generation, 20(1). https://doi.org/10.1049/rpg2.70316
Vancouver
Barrera K, Vidal Y. Explainable Early Fault Detection in Wind Turbine Generators Using Only SCADA Data From an Operational Wind Farm. IET Renewable Power Generation. 2026;20(1). doi:10.1049/rpg2.70316
BibTeX
@article{Barrera2026,
author = {Barrera, Kevin and Vidal, Yolanda},
title = {Explainable Early Fault Detection in Wind Turbine Generators Using Only SCADA Data From an Operational Wind Farm},
journal = {IET Renewable Power Generation},
year = {2026},
volume = {20},
number = {1},
doi = {10.1049/rpg2.70316}
}