Sustainable Energy Solutions for Healthcare Facilities in Developing Countries: A Hybrid System Analysis With HOMER Pro
IET Renewable Power Generation · 2026-01 · 20 (1)
DOI: 10.1049/rpg2.70231 ↗Kurz gefasst
Fachartikel in der Zeitschrift IET Renewable Power Generation, online erschienen am 15.03.2026. Verfasst von Md. Feroz Ali und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 101 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
On the verge of a severe power crisis in Bangladesh, this study investigates the optimisation of the hybrid renewable energy system (HRES) for the Baliakandi Upazila Health Complex. The high energy demands in health facilities call for sustainable and reliable solutions for the study. Hybrid Optimisation Model for Electric Renewables (HOMER) Pro software has been used to evaluate the six configurations that integrate solar PV, wind turbines, biogas generators, batteries, and grid connection. Case I emerged as the optimal configuration with the lowest cost of energy at $0.0329/kWh, a net present cost of $105,310, and an annual operating cost of $155.1. The system has a tremendous environmental impact in terms of the reduction in CO 2 emissions by approximately 70%, which is consistent with global climate goals. The hybrid system is ideal for rural settings due to its reliance on locally available renewable resources and the unreliability of grid connections. Although the payback period is extended, it would guarantee long‐term feasibility, cost savings, and environmental sustainability. Configurations with higher renewable integration, as in Cases I and II, were found to be more economical and environmentally friendly. Lower renewable usage meant increased emissions and costs. This research is important because uninterrupted and sustainable power supply is essential for health and educational institutions in Bangladesh, where frequent grid outages hinder reliable operation. The study provides a replicable hybrid renewable framework that can be applied to similar facilities in other developing countries to enhance energy security and reduce emissions. This study, thus, presents the potential of HRES in improving energy security and supporting sustainable health infrastructure in Bangladesh in support of both economic and environmental goals.
Zitieren
APA
Ali, M. F., Biswas, D., Sheikh, M. R. I., Rony, M. M. H., Hossain, M. R., Hossain, M. A., & Arefin, S. S. (2026). Sustainable Energy Solutions for Healthcare Facilities in Developing Countries: A Hybrid System Analysis With HOMER Pro. IET Renewable Power Generation, 20(1). https://doi.org/10.1049/rpg2.70231
Vancouver
Ali MF, Biswas D, Sheikh MRI, Rony MMH, Hossain MR, Hossain MA, et al. Sustainable Energy Solutions for Healthcare Facilities in Developing Countries: A Hybrid System Analysis With HOMER Pro. IET Renewable Power Generation. 2026;20(1). doi:10.1049/rpg2.70231
BibTeX
@article{Ali2026,
author = {Ali, Md. Feroz and Biswas, Diganto and Sheikh, Md. Rafiqul Islam and Rony, Md. Mahadi Hasan and Hossain, Md. Ripon and Hossain, Md. Alamgir and Arefin, Sk. Shezan},
title = {Sustainable Energy Solutions for Healthcare Facilities in Developing Countries: A Hybrid System Analysis With HOMER Pro},
journal = {IET Renewable Power Generation},
year = {2026},
volume = {20},
number = {1},
doi = {10.1049/rpg2.70231}
}
EUVIMED